Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2019
Principal Product Ready Mix Concrete
NAICS 327320 - Ready-Mix Concrete Manufacturing
SIC 3273 - Ready-mixed Concrete
Sales $500,000-$1,000,000
# of Employees 35
Plant Area (Sq.Ft.) 520,000
Annual Production 240,000 Units
Production Hrs. Annual 2,510
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $56,731 684,098 kWh $0.08
Electricity Demand $45,021 3,262 kW-months/year $13.80
Electricity Fees $2,133 - $ -
Natural Gas $43,235 7,049 MMBtu $6.13
TOTAL ENERGY COSTS $147,120
RECOMMENDED SAVINGS* $25,445 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $5,611
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$8,547
Cost:
$16,000
- - - - $8,547 1,393 - - -
-
kWh
-
-
kW-months/year
$8,547
1,393
MMBtu
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,388
Cost:
$4,793
$3,388 49,822 - - - - - - $3,388
49,822
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
03: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$3,383
Cost:
$1,450
$3,383 43,142 - - - - - - $3,383
43,142
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
04: 2.4112 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS Savings:
$3,382
Cost:
$4,600
$3,382 49,729 - - - - - - $3,382
49,729
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
05: 2.8112 COMBINE UTILITY METERS Savings:
$2,288
Cost:
$13,750
- - - - - - $2,288 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$2,288
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,028
Cost:
$3,476
$1,028 7,667 - - - - - - $1,028
7,667
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$961
Cost:
-
$623 9,155 $338 25 - - - - $623
9,155
kWh
$338
25
kW-months/year
-
-
MMBtu
-
-
$
08: 2.2511 INSULATE BARE EQUIPMENT Savings:
$806
Cost:
$2,350
- - - - $806 131 - - -
-
kWh
-
-
kW-months/year
$806
131
MMBtu
-
-
$
09: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$758
Cost:
$1,755
- - - - $758 124 - - -
-
kWh
-
-
kW-months/year
$758
124
MMBtu
-
-
$
10: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$504
Cost:
$200
$325 4,793 $179 13 - - - - $325
4,793
kWh
$179
13
kW-months/year
-
-
MMBtu
-
-
$
11: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$400
Cost:
$670
- - - - $400 65 - - -
-
kWh
-
-
kW-months/year
$400
65
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$25,445
Cost:
$49,044
$12,129 164,308 $518 38 $10,511 1,713 $2,288 - $12,129
164,308
kWh
$518
38
kW-months/year
$10,511
1,713
MMBtu
$2,288
-
$
TOTAL IMPLEMENTED Savings:
$5,611
Cost:
$6,748
$4,336 63,770 $518 38 $758 124 - - $4,336
63,770
kWh
$518
38
kW-months/year
$758
124
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes