Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2019 |
Principal Product | Ready Mix Concrete |
NAICS | 327320 - Ready-Mix Concrete Manufacturing |
SIC | 3273 - Ready-mixed Concrete |
Sales | $500,000-$1,000,000 |
# of Employees | 35 |
Plant Area (Sq.Ft.) | 520,000 |
Annual Production | 240,000 Units |
Production Hrs. Annual | 2,510 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $56,731 | 684,098 | kWh | $0.08 |
Electricity Demand | $45,021 | 3,262 | kW-months/year | $13.80 |
Electricity Fees | $2,133 | - | $ | - |
Natural Gas | $43,235 | 7,049 | MMBtu | $6.13 |
TOTAL ENERGY COSTS | $147,120 | |||
RECOMMENDED SAVINGS* | $25,445 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,611 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $8,547 Cost: $16,000 |
- | - | - | - | $8,547 | 1,393 | - | - |
- - kWh |
- - kW-months/year |
$8,547 1,393 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,388 Cost: $4,793 |
$3,388 | 49,822 | - | - | - | - | - | - |
$3,388 49,822 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $3,383 Cost: $1,450 |
$3,383 | 43,142 | - | - | - | - | - | - |
$3,383 43,142 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4112 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS |
Savings: $3,382 Cost: $4,600 |
$3,382 | 49,729 | - | - | - | - | - | - |
$3,382 49,729 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.8112 COMBINE UTILITY METERS |
Savings: $2,288 Cost: $13,750 |
- | - | - | - | - | - | $2,288 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,288 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,028 Cost: $3,476 |
$1,028 | 7,667 | - | - | - | - | - | - |
$1,028 7,667 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $961 Cost: - |
$623 | 9,155 | $338 | 25 | - | - | - | - |
$623 9,155 kWh |
$338 25 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $806 Cost: $2,350 |
- | - | - | - | $806 | 131 | - | - |
- - kWh |
- - kW-months/year |
$806 131 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $758 Cost: $1,755 |
- | - | - | - | $758 | 124 | - | - |
- - kWh |
- - kW-months/year |
$758 124 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $504 Cost: $200 |
$325 | 4,793 | $179 | 13 | - | - | - | - |
$325 4,793 kWh |
$179 13 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $400 Cost: $670 |
- | - | - | - | $400 | 65 | - | - |
- - kWh |
- - kW-months/year |
$400 65 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $25,445 Cost: $49,044 |
$12,129 | 164,308 | $518 | 38 | $10,511 | 1,713 | $2,288 | - | $12,129 164,308 kWh |
$518 38 kW-months/year |
$10,511 1,713 MMBtu |
$2,288 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,611 Cost: $6,748 |
$4,336 | 63,770 | $518 | 38 | $758 | 124 | - | - | $4,336 63,770 kWh |
$518 38 kW-months/year |
$758 124 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |