IAC logo
IAC Assessment: WM0150
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WM0150
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2019
Principal Product OEM plastics Converting
NAICS 325211 - Plastics Material and Resin Manufacturing
SIC 2821 - Plastics Materials And Resins
Sales $50,000,000-$100,000,000
# of Employees 170
Plant Area (Sq.Ft.) 93,500
Annual Production 10,000 Units
Production Hrs. Annual 8,568
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $103,975 1,474,800 kWh $0.07
Electricity Demand $55,261 4,352 kW-months/year $12.70
Electricity Fees $7,631 - $ -
Natural Gas $18,130 2,965 MMBtu $6.11
TOTAL ENERGY COSTS $184,997
RECOMMENDED SAVINGS* $20,958 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$9,749
Cost:
$27,082
$7,915 111,479 $1,834 133 - - $7,915
111,479
kWh
$1,834
133
kW-months/year
-
-
MMBtu
02: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$3,677
Cost:
$3,000
$3,400 47,881 $278 20 - - $3,400
47,881
kWh
$278
20
kW-months/year
-
-
MMBtu
03: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$3,191
Cost:
$3,200
$3,191 44,942 - - - - $3,191
44,942
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$1,791
Cost:
$700
- - - - $1,791 293 -
-
kWh
-
-
kW-months/year
$1,791
293
MMBtu
05: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$1,170
Cost:
$570
- - - - $1,170 191 -
-
kWh
-
-
kW-months/year
$1,170
191
MMBtu
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$980
Cost:
$1,950
- - - - $980 160 -
-
kWh
-
-
kW-months/year
$980
160
MMBtu
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$400
Cost:
$675
$400 5,616 - - - - $400
5,616
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$20,958
Cost:
$37,177
$14,906 209,918 $2,112 153 $3,941 644 $14,906
209,918
kWh
$2,112
153
kW-months/year
$3,941
644
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas