Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2020
Principal Product Potable Drinking Water and Treat Wastewater
NAICS 221320 - Sewage Treatment Facilities
SIC 4952 - Sewerage Systems
Sales <$500,000
# of Employees 12
Plant Area (Sq.Ft.) 1,082,000
Annual Production 15,000 Thousand Gallons
Production Hrs. Annual 8,736
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $322,996 4,708,194 kWh $0.07
Electricity Demand $168,753 13,471 kW-months/year $12.53
Electricity Fees $27,165 - $ -
Natural Gas $38,300 7,287 MMBtu $5.26
TOTAL ENERGY COSTS $557,214
RECOMMENDED SAVINGS* $52,856 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,028
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$20,527
Cost:
$105,000
$20,527 276,867 - - - - $20,527
276,867
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$11,563
Cost:
$3,300
$11,563 168,554 - - - - $11,563
168,554
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.6215 SHUT OFF AIR CONDITIONING IN WINTER HEATING SEASON Savings:
$9,593
Cost:
-
- - - - $9,593 1,810 -
-
kWh
-
-
kW-months/year
$9,593
1,810
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,847
Cost:
$13,133
$4,215 61,448 $632 50 - - $4,215
61,448
kWh
$632
50
kW-months/year
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,864
Cost:
$3,527
$1,864 27,174 - - - - $1,864
27,174
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$1,164
Cost:
-
$562 8,188 - - $602 114 $562
8,188
kWh
-
-
kW-months/year
$602
114
MMBtu
07: 2.2426 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR Savings:
$1,144
Cost:
$4,600
- - - - $1,144 216 -
-
kWh
-
-
kW-months/year
$1,144
216
MMBtu
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,058
Cost:
-
$845 12,317 $213 17 - - $845
12,317
kWh
$213
17
kW-months/year
-
-
MMBtu
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$554
Cost:
$2,225
$493 7,176 $61 5 - - $493
7,176
kWh
$61
5
kW-months/year
-
-
MMBtu
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$542
Cost:
$1,785
$433 6,317 $109 9 - - $433
6,317
kWh
$109
9
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$52,856
Cost:
$133,570
$40,502 568,041 $1,015 81 $11,339 2,139 $40,502
568,041
kWh
$1,015
81
kW-months/year
$11,339
2,139
MMBtu
TOTAL IMPLEMENTED Savings:
$3,028
Cost:
$3,527
$2,426 35,362 - - $602 114 $2,426
35,362
kWh
-
-
kW-months/year
$602
114
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas