Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2023
Principal Product Industrial Equipment
NAICS 333249 - Other Industrial Machinery Manufacturing
SIC 3559 - Special Industry Machinery, Nec
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 200,000
Annual Production 1,000 Units
Production Hrs. Annual 2,475
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $150,952 1,898,526 kWh $0.08
Electricity Demand $76,989 6,627 kW-months/year $11.62
Electricity Fees $21,234 - $ -
Natural Gas $36,002 5,594 MMBtu $6.44
TOTAL ENERGY COSTS $285,177
RECOMMENDED SAVINGS* $18,608 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$7,891
Cost:
-
$7,891 99,254 - - - - $7,891
99,254
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$4,429
Cost:
-
$2,374 29,864 $1,424 123 $631 98 $2,374
29,864
kWh
$1,424
123
kW-months/year
$631
98
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,139
Cost:
$3,096
$1,337 16,821 $802 69 - - $1,337
16,821
kWh
$802
69
kW-months/year
-
-
MMBtu
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$1,894
Cost:
$7,480
$1,894 23,822 - - - - $1,894
23,822
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$892
Cost:
$1,307
$577 7,259 $315 27 - - $577
7,259
kWh
$315
27
kW-months/year
-
-
MMBtu
06: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$781
Cost:
$1,300
- - - - $781 121 -
-
kWh
-
-
kW-months/year
$781
121
MMBtu
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$582
Cost:
$1,595
$529 6,654 $53 5 - - $529
6,654
kWh
$53
5
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$18,608
Cost:
$14,778
$14,603 183,674 $2,594 223 $1,411 219 $14,603
183,674
kWh
$2,594
223
kW-months/year
$1,411
219
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas