IAC logo
IAC Assessment: WM0217
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WM0217
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2024
Principal Product wastewater
NAICS 221320 - Sewage Treatment Facilities
SIC 4952 - Sewerage Systems
Sales <$500,000
# of Employees 4
Plant Area (Sq.Ft.) 44,888
Annual Production 2,920,000 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $364,198 7,193,879 kWh $0.05
Electricity Demand $176,323 12,925 kW-months/year $13.64
Electricity Fees $38,373 - $ -
Natural Gas $56,257 6,140 MMBtu $9.16
TOTAL ENERGY COSTS $635,151
RECOMMENDED SAVINGS* $14,800 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$9,218
Cost:
$9,231
- - - - $9,218 1,006 -
-
kWh
-
-
kW-months/year
$9,218
1,006
MMBtu
02: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$2,160
Cost:
-
$2,160 42,336 - - - - $2,160
42,336
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$1,253
Cost:
$882
- - - - $1,253 137 -
-
kWh
-
-
kW-months/year
$1,253
137
MMBtu
04: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$1,029
Cost:
-
$367 7,191 $134 10 $529 58 $367
7,191
kWh
$134
10
kW-months/year
$529
58
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$564
Cost:
$632
$306 6,001 $258 19 - - $306
6,001
kWh
$258
19
kW-months/year
-
-
MMBtu
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$320
Cost:
$180
$235 4,600 $86 6 - - $235
4,600
kWh
$86
6
kW-months/year
-
-
MMBtu
07: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$255
Cost:
$480
$138 2,711 $117 9 - - $138
2,711
kWh
$117
9
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$14,800
Cost:
$11,405
$3,206 62,839 $595 44 $11,000 1,201 $3,206
62,839
kWh
$595
44
kW-months/year
$11,000
1,201
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas