IAC logo
IAC Assessment: WM0226
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WM0226
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2024
Principal Product Used Medical Devices and Equipment
NAICS 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
SIC 3845 - Electromedical Equipment
Sales $10,000,000-$50,000,000
# of Employees 200
Plant Area (Sq.Ft.) 300,000
Annual Production 5,000 Units
Production Hrs. Annual 2,040
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $187,331 2,714,407 kWh $0.07
Electricity Demand $138,703 7,574 kW-months/year $18.31
Electricity Fees $18,264 - $ -
Natural Gas $44,814 7,092 MMBtu $6.32
TOTAL ENERGY COSTS $393,686
RECOMMENDED SAVINGS* $52,209 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$31,974
Cost:
$246,400
$25,049 363,043 $6,925 378 - - $25,049
363,043
kWh
$6,925
378
kW-months/year
-
-
MMBtu
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$7,290
Cost:
-
$3,311 47,981 $3,979 217 - - $3,311
47,981
kWh
$3,979
217
kW-months/year
-
-
MMBtu
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$6,027
Cost:
$9,016
$(-519) 7,522 - - $6,546 1,036 $(-519)
7,522
kWh
-
-
kW-months/year
$6,546
1,036
MMBtu
04: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$5,832
Cost:
$2,000
- - - - $5,832 923 -
-
kWh
-
-
kW-months/year
$5,832
923
MMBtu
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$835
Cost:
$198
$835 12,096 - - - - $835
12,096
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$251
Cost:
$460
$251 3,633 - - - - $251
3,633
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$52,209
Cost:
$258,074
$28,926 434,275 $10,905 595 $12,378 1,959 $28,926
434,275
kWh
$10,905
595
kW-months/year
$12,378
1,959
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas