Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 1994
Principal Product Bearings
NAICS n/a
SIC 3562 - Ball And Roller Bearings
Sales $50,000,000-$100,000,000
# of Employees 280
Plant Area (Sq.Ft.) 300,000
Annual Production 12,000,000 Pieces
Production Hrs. Annual 6,720
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $760,731 15,663,248 kWh $0.05
Natural Gas $155,105 33,095 MMBtu $4.69
TOTAL ENERGY COSTS $915,836
RECOMMENDED SAVINGS* $37,305 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $14,753
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,279
Cost:
$7,375
$4,279 177,022 - - $4,279
177,022
kWh
-
-
MMBtu
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,921
Cost:
-
$1,921 79,426 - - $1,921
79,426
kWh
-
-
MMBtu
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$2,094
Cost:
$1,372
$2,094 86,753 - - $2,094
86,753
kWh
-
-
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$3,973
Cost:
$440
- - $3,973 847 -
-
kWh
$3,973
847
MMBtu
05: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$3,391
Cost:
$4,400
- - $3,391 728 -
-
kWh
$3,391
728
MMBtu
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$11,021
Cost:
$6,660
- - $11,021 2,350 -
-
kWh
$11,021
2,350
MMBtu
07: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$340
Cost:
$200
$340 14,068 - - $340
14,068
kWh
-
-
MMBtu
08: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$2,246
Cost:
-
$2,246 92,907 - - $2,246
92,907
kWh
-
-
MMBtu
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$8,040
Cost:
$35,000
$8,040 332,943 - - $8,040
332,943
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$37,305
Cost:
$55,447
$18,920 783,119 $18,385 3,925 $18,920
783,119
kWh
$18,385
3,925
MMBtu
TOTAL IMPLEMENTED Savings:
$14,753
Cost:
$43,947
$14,753 610,786 - - $14,753
610,786
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas