Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 1996
Principal Product Windows and Doors
NAICS n/a
SIC 2431 - Millwork
Sales $10,000,000-$50,000,000
# of Employees 320
Plant Area (Sq.Ft.) 480,000
Annual Production 220,000 Pieces
Production Hrs. Annual 3,825
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $175,886 5,127,784 kWh $0.03
Electricity Demand $73,732 15,328 kW-months/year $4.81
Natural Gas $50,973 18,541 MMBtu $2.75
TOTAL ENERGY COSTS $300,591
RECOMMENDED SAVINGS* $15,056 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,632
#|Description Savings
Cost
Status Electricity Usage Natural Gas Water Disposal Administrative Changes Electricity Usage Natural Gas Water Disposal Administrative Changes
$ kWh $ MMBtu $ Tgal $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,916
Cost:
$7,418
$4,916 225,381 - - - - - - $4,916
225,381
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$438
Cost:
$420
$438 19,930 - - - - - - $438
19,930
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$530
Cost:
$200
$530 24,326 - - - - - - $530
24,326
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,316
Cost:
$300
$1,316 60,375 - - - - - - $1,316
60,375
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$847
Cost:
$2,000
- - $847 308 - - - - -
-
kWh
$847
308
MMBtu
-
-
Tgal
-
-
$
06: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$1,962
Cost:
$2,884
- - $1,962 722 - - - - -
-
kWh
$1,962
722
MMBtu
-
-
Tgal
-
-
$
07: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION Savings:
$5,047
Cost:
$5,400
$(-519) (-23,740) - - $5,651 14,406 $(-85) - $(-519)
(-23,740)
kWh
-
-
MMBtu
$5,651
14,406
Tgal
$(-85)
-
$
TOTAL RECOMMENDED Savings:
$15,056
Cost:
$18,622
$6,681 306,272 $2,809 1,030 $5,651 14,406 $(-85) - $6,681
306,272
kWh
$2,809
1,030
MMBtu
$5,651
14,406
Tgal
$(-85)
-
$
TOTAL IMPLEMENTED Savings:
$8,632
Cost:
$11,022
$6,670 305,686 $1,962 722 - - - - $6,670
305,686
kWh
$1,962
722
MMBtu
-
-
Tgal
-
-
$
Savings
Cost
$ kWh $ MMBtu $ Tgal $ $
Electricity Usage Natural Gas Water Disposal Administrative Changes Electricity Usage Natural Gas Water Disposal Administrative Changes