Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 1996 |
Principal Product | Vinyl Windows |
NAICS | n/a |
SIC | 3442 - Metal Doors, Sash, And Trim |
Sales | $10,000,000-$50,000,000 |
# of Employees | 320 |
Plant Area (Sq.Ft.) | 165,000 |
Annual Production | 200,000 Pieces |
Production Hrs. Annual | 6,120 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $107,794 | 2,963,072 | kWh | $0.04 |
Electricity Demand | $44,777 | 8,910 | kW-months/year | $5.03 |
Electricity Fees | $8,536 | - | $ | - |
Natural Gas | $34,704 | 6,103 | MMBtu | $5.69 |
TOTAL ENERGY COSTS | $195,811 | |||
RECOMMENDED SAVINGS* | $20,503 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $18,445 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Natural Gas | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,497 Cost: $4,364 |
$1,497 | 41,911 | - | - | - | - | - | - |
$1,497 41,911 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $888 Cost: $1,040 |
$888 | 24,912 | - | - | - | - | - | - |
$888 24,912 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $491 Cost: $375 |
$491 | 13,775 | - | - | - | - | - | - |
$491 13,775 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $642 Cost: $45 |
$642 | 17,878 | - | - | - | - | - | - |
$642 17,878 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $3,521 Cost: $3,800 |
$3,521 | 98,769 | - | - | - | - | - | - |
$3,521 98,769 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $3,123 Cost: $2,800 |
$(-52) | (-1,465) | $3,175 | 558 | - | - | - | - |
$(-52) (-1,465) kWh |
$3,175 558 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $925 Cost: $920 |
- | - | $925 | 162 | - | - | - | - |
- - kWh |
$925 162 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $2,592 Cost: $1,495 |
- | - | $2,592 | 455 | - | - | - | - |
- - kWh |
$2,592 455 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $2,321 Cost: $534 |
- | - | $2,321 | 408 | - | - | - | - |
- - kWh |
$2,321 408 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $4,503 Cost: $8,000 |
$(-60) | (-1,172) | - | - | $(-2,250) | - | $6,813 | - |
$(-60) (-1,172) kWh |
- - MMBtu |
$(-2,250) - $ |
$6,813 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $20,503 Cost: $23,373 |
$6,927 | 194,608 | $9,013 | 1,583 | $(-2,250) | - | $6,813 | - | $6,927 194,608 kWh |
$9,013 1,583 MMBtu |
$(-2,250) - $ |
$6,813 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $18,445 Cost: $22,033 |
$5,794 | 162,955 | $8,088 | 1,421 | $(-2,250) | - | $6,813 | - | $5,794 162,955 kWh |
$8,088 1,421 MMBtu |
$(-2,250) - $ |
$6,813 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Natural Gas | Administrative Changes | Ancillary Material Cost |