Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 1996 |
Principal Product | Vinyl Drapes and Blinds |
NAICS | n/a |
SIC | 2391 - Curtains And Draperies |
Sales | $10,000,000-$50,000,000 |
# of Employees | 285 |
Plant Area (Sq.Ft.) | 90,000 |
Annual Production | 600,600 Pieces |
Production Hrs. Annual | 5,148 |
Location (State) | MD |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $12,705 | 851,700 | kWh | $0.01 |
Electricity Demand | $26,192 | 2,320 | kW-months/year | $11.29 |
Electricity Fees | $15,077 | - | $ | - |
LPG | $20,332 | 2,972 | MMBtu | $6.84 |
TOTAL ENERGY COSTS | $74,306 | |||
RECOMMENDED SAVINGS* | $13,386 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,058 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | LPG | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,328 Cost: $3,412 |
$795 | 26,964 | $1,533 | 136 | - | - | - | - | - | - |
$795 26,964 kWh |
$1,533 136 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $1,096 Cost: $2,734 |
$1,096 | 37,222 | - | - | - | - | - | - | - | - |
$1,096 37,222 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $4,424 Cost: $3,000 |
- | - | - | - | $4,424 | 647 | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,424 647 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $1,531 Cost: $150 |
- | - | - | - | - | - | - | - | $1,531 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$1,531 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $1,927 Cost: $5,000 |
- | - | - | - | - | - | $(-1,286) | - | $3,213 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$(-1,286) - $ |
$3,213 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $2,080 Cost: $200 |
- | - | - | - | - | - | - | - | $2,080 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$2,080 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $13,386 Cost: $14,496 |
$1,891 | 64,186 | $1,533 | 136 | $4,424 | 647 | $(-1,286) | - | $6,824 | - | $1,891 64,186 kWh |
$1,533 136 kW-months/year |
$4,424 647 MMBtu |
$(-1,286) - $ |
$6,824 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,058 Cost: $11,084 |
$1,096 | 37,222 | - | - | $4,424 | 647 | $(-1,286) | - | $6,824 | - | $1,096 37,222 kWh |
- - kW-months/year |
$4,424 647 MMBtu |
$(-1,286) - $ |
$6,824 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | LPG | Personnel Changes | Administrative Changes |