Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 1998 |
Principal Product | Flat glass |
NAICS | n/a |
SIC | 3211 - Flat Glass |
Sales | $10,000,000-$50,000,000 |
# of Employees | 110 |
Plant Area (Sq.Ft.) | 225,000 |
Annual Production | 500 Thousand Feet |
Production Hrs. Annual | 6,240 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $329,041 | 8,627,198 | kWh | $0.04 |
Electricity Demand | $223,882 | 20,675 | kW-months/year | $10.83 |
Electricity Fees | $11,261 | - | $ | - |
Natural Gas | $132,021 | 35,163 | MMBtu | $3.75 |
TOTAL ENERGY COSTS | $696,205 | |||
RECOMMENDED SAVINGS* | $50,362 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $26,815 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Other Gas | Solid Waste (non-haz) | Solid Waste (haz) | Administrative Changes | Electricity Usage | Natural Gas | Other Gas | Solid Waste (non-haz) | Solid Waste (haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | $ | lb | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $6,254 Cost: $2,580 |
$6,254 | 158,558 | - | - | - | - | - | - | - | - | - | - |
$6,254 158,558 kWh |
- - MMBtu |
- - MMBtu |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $758 Cost: $700 |
- | - | $758 | 202 | - | - | - | - | - | - | - | - |
- - kWh |
$758 202 MMBtu |
- - MMBtu |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $5,558 Cost: $2,600 |
- | - | $5,558 | 1,482 | - | - | - | - | - | - | - | - |
- - kWh |
$5,558 1,482 MMBtu |
- - MMBtu |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $447 Cost: $171 |
- | - | $447 | 119 | - | - | - | - | - | - | - | - |
- - kWh |
$447 119 MMBtu |
- - MMBtu |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $236 Cost: $732 |
- | - | $236 | 63 | - | - | - | - | - | - | - | - |
- - kWh |
$236 63 MMBtu |
- - MMBtu |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,785 Cost: $1,355 |
- | - | $1,785 | 476 | - | - | - | - | - | - | - | - |
- - kWh |
$1,785 476 MMBtu |
- - MMBtu |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1331 BURN A LESS EXPENSIVE GRADE OF FUEL |
Savings: $9,550 Cost: $8,400 |
- | - | - | - | $9,550 | - | - | - | - | - | - | - |
- - kWh |
- - MMBtu |
$9,550 - MMBtu |
- - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $960 Cost: $50 |
- | - | - | - | - | - | $960 | - | - | - | - | - |
- - kWh |
- - MMBtu |
- - MMBtu |
$960 - lb |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5318 RECYCLE FLUORESCENT LAMPS |
Savings: $400 Cost: $45 |
- | - | - | - | - | - | - | - | $400 | - | - | - |
- - kWh |
- - MMBtu |
- - MMBtu |
- - lb |
$400 - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $24,414 Cost: $3,000 |
- | - | - | - | - | - | - | - | - | - | $24,414 | - |
- - kWh |
- - MMBtu |
- - MMBtu |
- - lb |
- - lb |
$24,414 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $50,362 Cost: $19,633 |
$6,254 | 158,558 | $8,784 | 2,342 | $9,550 | - | $960 | - | $400 | - | $24,414 | - | $6,254 158,558 kWh |
$8,784 2,342 MMBtu |
$9,550 - MMBtu |
$960 - lb |
$400 - lb |
$24,414 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $26,815 Cost: $4,653 |
- | - | $1,441 | 384 | - | - | $960 | - | - | - | $24,414 | - | - - kWh |
$1,441 384 MMBtu |
- - MMBtu |
$960 - lb |
- - lb |
$24,414 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | $ | lb | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Other Gas | Solid Waste (non-haz) | Solid Waste (haz) | Administrative Changes | Electricity Usage | Natural Gas | Other Gas | Solid Waste (non-haz) | Solid Waste (haz) | Administrative Changes |