Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 1999 |
Principal Product | Decorative glass |
NAICS | n/a |
SIC | 3211 - Flat Glass |
Sales | $1,000,000-$5,000,000 |
# of Employees | 30 |
Plant Area (Sq.Ft.) | 25,000 |
Annual Production | 1,000 Thousand Feet |
Production Hrs. Annual | 4,335 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $18,416 | 285,756 | kWh | $0.06 |
Natural Gas | $41,769 | 7,832 | MMBtu | $5.33 |
TOTAL ENERGY COSTS | $60,185 | |||
RECOMMENDED SAVINGS* | $70,110 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $30,194 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | LPG | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Natural Gas | LPG | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $12,173 Cost: $1,000 |
- | - | $12,173 | 2,284 | - | - | - | - | - | - |
- - kWh |
$12,173 2,284 MMBtu |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $809 Cost: $315 |
$809 | 12,603 | - | - | - | - | - | - | - | - |
$809 12,603 kWh |
- - MMBtu |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $5,901 Cost: $606 |
- | - | $5,901 | 1,180 | - | - | - | - | - | - |
- - kWh |
$5,901 1,180 MMBtu |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1331 BURN A LESS EXPENSIVE GRADE OF FUEL |
Savings: $22,359 Cost: $12,500 |
- | - | $(-27,730) | (-4,487) | $50,089 | 3,902 | - | - | - | - |
- - kWh |
$(-27,730) (-4,487) MMBtu |
$50,089 3,902 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $11,784 Cost: $10,000 |
- | - | - | - | - | - | - | - | $11,784 | - |
- - kWh |
- - MMBtu |
- - MMBtu |
- - lb |
$11,784 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $804 Cost: $5,500 |
- | - | - | - | - | - | $804 | - | - | - |
- - kWh |
- - MMBtu |
- - MMBtu |
$804 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.113 INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT |
Savings: $12,120 Cost: $800 |
- | - | - | - | - | - | - | - | $12,120 | - |
- - kWh |
- - MMBtu |
- - MMBtu |
- - lb |
$12,120 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.214 PURCHASE APPROPRIATELY SIZED MATERIAL |
Savings: $4,160 Cost: - |
- | - | - | - | - | - | - | - | $4,160 | - |
- - kWh |
- - MMBtu |
- - MMBtu |
- - lb |
$4,160 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $70,110 Cost: $30,721 |
$809 | 12,603 | $(-9,656) | (-1,023) | $50,089 | 3,902 | $804 | - | $28,064 | - | $809 12,603 kWh |
$(-9,656) (-1,023) MMBtu |
$50,089 3,902 MMBtu |
$804 - lb |
$28,064 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $30,194 Cost: $2,406 |
- | - | $18,074 | 3,464 | - | - | - | - | $12,120 | - | - - kWh |
$18,074 3,464 MMBtu |
- - MMBtu |
- - lb |
$12,120 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | LPG | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Natural Gas | LPG | Solid Waste (non-haz) | Administrative Changes |