Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2004 |
Principal Product | Carded Packaging |
NAICS | 322220 - Paper Bag and Coated and Treated Paper Manufacturing |
SIC | 2679 - Converted Paper Products, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 175 |
Plant Area (Sq.Ft.) | 185,000 |
Annual Production | 15,000 Tons |
Production Hrs. Annual | 6,552 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $217,008 | 4,337,280 | kWh | $0.05 |
Electricity Demand | $83,014 | 14,318 | kW-months/year | $5.80 |
Natural Gas | $21,605 | 2,929 | MMBtu | $7.38 |
TOTAL ENERGY COSTS | $321,627 | |||
RECOMMENDED SAVINGS* | $567,139 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $16,780 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Primary Product | Electricity Usage | Electricity Demand | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $30,792 Cost: $30,627 |
$30,258 | 604,799 | $534 | 92 | - | - |
$30,258 604,799 kWh |
$534 92 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $10,219 Cost: $4,900 |
$8,430 | 168,350 | $1,789 | 26 | - | - |
$8,430 168,350 kWh |
$1,789 26 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $5,704 Cost: $230 |
$4,706 | 94,053 | $998 | 172 | - | - |
$4,706 94,053 kWh |
$998 172 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $4,247 Cost: $2,660 |
$3,841 | 76,712 | $406 | 70 | - | - |
$3,841 76,712 kWh |
$406 70 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.623 EMPLOY MODULAR JIGS TO REDUCE PROCESS SET-UP TIME |
Savings: $509,116 Cost: $20,000 |
$2,668 | 53,228 | - | - | $506,448 | - |
$2,668 53,228 kWh |
- - kW-months/year |
$506,448 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $2,472 Cost: $920 |
$2,039 | 40,758 | $433 | 75 | - | - |
$2,039 40,758 kWh |
$433 75 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,431 Cost: $784 |
$2,008 | 40,141 | $423 | 73 | - | - |
$2,008 40,141 kWh |
$423 73 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,317 Cost: $215 |
$1,085 | 21,751 | $232 | 40 | - | - |
$1,085 21,751 kWh |
$232 40 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $609 Cost: $46 |
$400 | 7,992 | $209 | 3 | - | - |
$400 7,992 kWh |
$209 3 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $232 Cost: $129 |
$190 | 3,974 | $42 | 7 | - | - |
$190 3,974 kWh |
$42 7 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $567,139 Cost: $60,511 |
$55,625 | 1,111,758 | $5,066 | 557 | $506,448 | - | $55,625 1,111,758 kWh |
$5,066 557 kW-months/year |
$506,448 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $16,780 Cost: $4,855 |
$14,079 | 281,407 | $2,701 | 433 | - | - | $14,079 281,407 kWh |
$2,701 433 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Primary Product | Electricity Usage | Electricity Demand | Primary Product |