Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2008 |
Principal Product | Lumber |
NAICS | 321113 - Sawmills |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $10,000,000-$50,000,000 |
# of Employees | 175 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 18,000,000 Units |
Production Hrs. Annual | 2,678 |
Location (State) | WV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $369,024 | 12,451,472 | kWh | $0.03 |
Electricity Demand | $265,701 | 30,526 | kW-months/year | $8.70 |
Electricity Fees | $406 | - | $ | - |
TOTAL ENERGY COSTS | $635,131 | |||
RECOMMENDED SAVINGS* | $913,782 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $39,792 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Wood | Other Energy | Personnel Changes | Electricity Usage | Electricity Demand | Wood | Other Energy | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3414 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT |
Savings: $870,056 Cost: $3,850,000 |
$201,660 | 6,812,832 | $168,815 | 19,404 | $(-55,488) | - | $555,069 | 63,148 | - | - |
$201,660 6,812,832 kWh |
$168,815 19,404 kW-months/year |
$(-55,488) - MMBtu |
$555,069 63,148 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $16,386 Cost: $3,500 |
$7,553 | 255,180 | $9,948 | 1,143 | - | - | - | - | $(-1,115) | - |
$7,553 255,180 kWh |
$9,948 1,143 kW-months/year |
- - MMBtu |
- - MMBtu |
$(-1,115) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $11,577 Cost: $1,336 |
$5,035 | 170,114 | $6,632 | 762 | - | - | - | - | $(-90) | - |
$5,035 170,114 kWh |
$6,632 762 kW-months/year |
- - MMBtu |
- - MMBtu |
$(-90) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $9,511 Cost: - |
$4,104 | 138,589 | $5,407 | 622 | - | - | - | - | - | - |
$4,104 138,589 kWh |
$5,407 622 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,892 Cost: $485 |
$1,248 | 42,179 | $1,644 | 189 | - | - | - | - | - | - |
$1,248 42,179 kWh |
$1,644 189 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,538 Cost: - |
$981 | 33,138 | $557 | 64 | - | - | - | - | - | - |
$981 33,138 kWh |
$557 64 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,042 Cost: $185 |
$554 | 18,713 | $488 | 56 | - | - | - | - | - | - |
$554 18,713 kWh |
$488 56 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $780 Cost: $2,158 |
$336 | 11,352 | $444 | 51 | - | - | - | - | - | - |
$336 11,352 kWh |
$444 51 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $913,782 Cost: $3,857,664 |
$221,471 | 7,482,097 | $193,935 | 22,291 | $(-55,488) | - | $555,069 | 63,148 | $(-1,205) | - | $221,471 7,482,097 kWh |
$193,935 22,291 kW-months/year |
$(-55,488) - MMBtu |
$555,069 63,148 MMBtu |
$(-1,205) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $39,792 Cost: $6,994 |
$18,009 | 608,373 | $22,988 | 2,642 | - | - | - | - | $(-1,205) | - | $18,009 608,373 kWh |
$22,988 2,642 kW-months/year |
- - MMBtu |
- - MMBtu |
$(-1,205) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Wood | Other Energy | Personnel Changes | Electricity Usage | Electricity Demand | Wood | Other Energy | Personnel Changes |