Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 2009
Principal Product Recreational Vehicles
NAICS 336213 - Motor Home Manufacturing
SIC 3716 - Motor Homes
Sales $10,000,000-$50,000,000
# of Employees 300
Plant Area (Sq.Ft.) 286,000
Annual Production 950 Pieces
Production Hrs. Annual 2,000
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $101,746 2,639,232 kWh $0.04
Electricity Demand $75,051 10,024 kW-months/year $7.49
Electricity Fees $2,689 - $ -
Natural Gas $189,941 16,217 MMBtu $11.71
TOTAL ENERGY COSTS $369,427
RECOMMENDED SAVINGS* $82,730 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $30,743
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$48,632
Cost:
$54,244
- - - - $48,632 4,153 - - -
-
kWh
-
-
kW-months/year
$48,632
4,153
MMBtu
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$15,117
Cost:
$51,755
$7,028 182,302 $8,089 1,080 - - - - $7,028
182,302
kWh
$8,089
1,080
kW-months/year
-
-
MMBtu
-
-
$
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$3,159
Cost:
$1,876
$1,459 37,853 $1,700 227 - - - - $1,459
37,853
kWh
$1,700
227
kW-months/year
-
-
MMBtu
-
-
$
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$3,130
Cost:
$1,763
$(-47) (-1,229) $(-55) (-7) $3,232 276 - - $(-47)
(-1,229)
kWh
$(-55)
(-7)
kW-months/year
$3,232
276
MMBtu
-
-
$
05: 2.4151 DEVELOP A REPAIR/REPLACE POLICY Savings:
$2,746
Cost:
$560
$1,315 34,116 $1,533 205 - - $(-102) - $1,315
34,116
kWh
$1,533
205
kW-months/year
-
-
MMBtu
$(-102)
-
$
06: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$2,424
Cost:
$6,259
- - - - $2,424 207 - - -
-
kWh
-
-
kW-months/year
$2,424
207
MMBtu
-
-
$
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,366
Cost:
$3,122
$1,093 28,348 $1,273 170 - - - - $1,093
28,348
kWh
$1,273
170
kW-months/year
-
-
MMBtu
-
-
$
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,801
Cost:
$34
$775 22,905 $1,026 137 - - - - $775
22,905
kWh
$1,026
137
kW-months/year
-
-
MMBtu
-
-
$
09: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$1,757
Cost:
$4,680
- - - - $1,757 150 - - -
-
kWh
-
-
kW-months/year
$1,757
150
MMBtu
-
-
$
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$749
Cost:
$572
$344 8,933 $405 54 - - - - $344
8,933
kWh
$405
54
kW-months/year
-
-
MMBtu
-
-
$
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$321
Cost:
-
$149 3,864 $172 23 - - - - $149
3,864
kWh
$172
23
kW-months/year
-
-
MMBtu
-
-
$
12: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD Savings:
$282
Cost:
$590
$95 2,462 $187 25 - - - - $95
2,462
kWh
$187
25
kW-months/year
-
-
MMBtu
-
-
$
13: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$246
Cost:
$400
- - - - $246 21 - - -
-
kWh
-
-
kW-months/year
$246
21
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$82,730
Cost:
$125,855
$12,211 319,554 $14,330 1,914 $56,291 4,807 $(-102) - $12,211
319,554
kWh
$14,330
1,914
kW-months/year
$56,291
4,807
MMBtu
$(-102)
-
$
TOTAL IMPLEMENTED Savings:
$30,743
Cost:
$65,369
$11,623 304,295 $13,566 1,812 $5,656 483 $(-102) - $11,623
304,295
kWh
$13,566
1,812
kW-months/year
$5,656
483
MMBtu
$(-102)
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes