Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2009 |
Principal Product | Recreational Vehicles |
NAICS | 336213 - Motor Home Manufacturing |
SIC | 3716 - Motor Homes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 286,000 |
Annual Production | 950 Pieces |
Production Hrs. Annual | 2,000 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $101,746 | 2,639,232 | kWh | $0.04 |
Electricity Demand | $75,051 | 10,024 | kW-months/year | $7.49 |
Electricity Fees | $2,689 | - | $ | - |
Natural Gas | $189,941 | 16,217 | MMBtu | $11.71 |
TOTAL ENERGY COSTS | $369,427 | |||
RECOMMENDED SAVINGS* | $82,730 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $30,743 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $48,632 Cost: $54,244 |
- | - | - | - | $48,632 | 4,153 | - | - |
- - kWh |
- - kW-months/year |
$48,632 4,153 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $15,117 Cost: $51,755 |
$7,028 | 182,302 | $8,089 | 1,080 | - | - | - | - |
$7,028 182,302 kWh |
$8,089 1,080 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,159 Cost: $1,876 |
$1,459 | 37,853 | $1,700 | 227 | - | - | - | - |
$1,459 37,853 kWh |
$1,700 227 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $3,130 Cost: $1,763 |
$(-47) | (-1,229) | $(-55) | (-7) | $3,232 | 276 | - | - |
$(-47) (-1,229) kWh |
$(-55) (-7) kW-months/year |
$3,232 276 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $2,746 Cost: $560 |
$1,315 | 34,116 | $1,533 | 205 | - | - | $(-102) | - |
$1,315 34,116 kWh |
$1,533 205 kW-months/year |
- - MMBtu |
$(-102) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $2,424 Cost: $6,259 |
- | - | - | - | $2,424 | 207 | - | - |
- - kWh |
- - kW-months/year |
$2,424 207 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,366 Cost: $3,122 |
$1,093 | 28,348 | $1,273 | 170 | - | - | - | - |
$1,093 28,348 kWh |
$1,273 170 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,801 Cost: $34 |
$775 | 22,905 | $1,026 | 137 | - | - | - | - |
$775 22,905 kWh |
$1,026 137 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $1,757 Cost: $4,680 |
- | - | - | - | $1,757 | 150 | - | - |
- - kWh |
- - kW-months/year |
$1,757 150 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $749 Cost: $572 |
$344 | 8,933 | $405 | 54 | - | - | - | - |
$344 8,933 kWh |
$405 54 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $321 Cost: - |
$149 | 3,864 | $172 | 23 | - | - | - | - |
$149 3,864 kWh |
$172 23 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $282 Cost: $590 |
$95 | 2,462 | $187 | 25 | - | - | - | - |
$95 2,462 kWh |
$187 25 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $246 Cost: $400 |
- | - | - | - | $246 | 21 | - | - |
- - kWh |
- - kW-months/year |
$246 21 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $82,730 Cost: $125,855 |
$12,211 | 319,554 | $14,330 | 1,914 | $56,291 | 4,807 | $(-102) | - | $12,211 319,554 kWh |
$14,330 1,914 kW-months/year |
$56,291 4,807 MMBtu |
$(-102) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $30,743 Cost: $65,369 |
$11,623 | 304,295 | $13,566 | 1,812 | $5,656 | 483 | $(-102) | - | $11,623 304,295 kWh |
$13,566 1,812 kW-months/year |
$5,656 483 MMBtu |
$(-102) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |