Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 2012
Principal Product Automobile Plastic Parts
NAICS 326199 - All Other Plastics Product Manufacturing
SIC 3089 - Plastics Products, Nec
Sales $100,000,000-$500,000,000
# of Employees 565
Plant Area (Sq.Ft.) 425,000
Annual Production 120,000,000 Pounds
Production Hrs. Annual 8,064
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,996,901 31,608,216 kWh $0.06
Electricity Demand $504,774 63,092 kW-months/year $8.00
Natural Gas $878,400 148,210 MMBtu $5.93
TOTAL ENERGY COSTS $3,380,075
RECOMMENDED SAVINGS* $450,272 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $151,122
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$186,348
Cost:
$102,956
$156,596 2,478,569 $29,752 3,719 - - - - $156,596
2,478,569
kWh
$29,752
3,719
kW-months/year
-
-
MMBtu
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$59,316
Cost:
$160,057
$49,908 789,937 $9,408 1,196 - - - - $49,908
789,937
kWh
$9,408
1,196
kW-months/year
-
-
MMBtu
-
-
$
03: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM Savings:
$39,551
Cost:
$6,000
$33,979 537,814 $6,400 800 - - $(-828) - $33,979
537,814
kWh
$6,400
800
kW-months/year
-
-
MMBtu
$(-828)
-
$
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$30,777
Cost:
$32,050
$30,777 487,138 - - - - - - $30,777
487,138
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
05: 2.4151 DEVELOP A REPAIR/REPLACE POLICY Savings:
$25,750
Cost:
$5,551
$23,434 370,906 $4,416 552 - - $(-2,100) - $23,434
370,906
kWh
$4,416
552
kW-months/year
-
-
MMBtu
$(-2,100)
-
$
06: 2.2426 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR Savings:
$22,024
Cost:
$43,600
- - - - $22,024 3,714 - - -
-
kWh
-
-
kW-months/year
$22,024
3,714
MMBtu
-
-
$
07: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$16,138
Cost:
$34,000
$8,298 131,344 $7,840 980 - - - - $8,298
131,344
kWh
$7,840
980
kW-months/year
-
-
MMBtu
-
-
$
08: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$13,230
Cost:
$31,450
- - - - $13,230 2,231 - - -
-
kWh
-
-
kW-months/year
$13,230
2,231
MMBtu
-
-
$
09: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$9,998
Cost:
$40,725
- - - - $9,998 1,686 - - -
-
kWh
-
-
kW-months/year
$9,998
1,686
MMBtu
-
-
$
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$9,620
Cost:
$2,000
$8,092 128,078 $1,528 191 - - - - $8,092
128,078
kWh
$1,528
191
kW-months/year
-
-
MMBtu
-
-
$
11: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$6,831
Cost:
$10,700
$6,831 108,117 - - - - - - $6,831
108,117
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
12: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$6,825
Cost:
$5,175
$5,745 90,933 $1,080 135 - - - - $5,745
90,933
kWh
$1,080
135
kW-months/year
-
-
MMBtu
-
-
$
13: 2.2113 REPAIR OR REPLACE STEAM TRAPS Savings:
$5,366
Cost:
$6,738
- - - - $6,766 1,141 $(-1,400) - -
-
kWh
-
-
kW-months/year
$6,766
1,141
MMBtu
$(-1,400)
-
$
14: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$5,361
Cost:
$998
$4,511 71,407 $850 106 - - - - $4,511
71,407
kWh
$850
106
kW-months/year
-
-
MMBtu
-
-
$
15: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$5,236
Cost:
$1,000
$4,406 69,734 $830 104 - - - - $4,406
69,734
kWh
$830
104
kW-months/year
-
-
MMBtu
-
-
$
16: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$2,093
Cost:
$6,840
- - - - $2,093 353 - - -
-
kWh
-
-
kW-months/year
$2,093
353
MMBtu
-
-
$
17: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$2,091
Cost:
$1,255
$1,707 27,019 $384 48 - - - - $1,707
27,019
kWh
$384
48
kW-months/year
-
-
MMBtu
-
-
$
18: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,749
Cost:
$4,020
$430 6,803 $80 10 $1,239 209 - - $430
6,803
kWh
$80
10
kW-months/year
$1,239
209
MMBtu
-
-
$
19: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$1,224
Cost:
$2,500
- - - - $1,382 233 $(-158) - -
-
kWh
-
-
kW-months/year
$1,382
233
MMBtu
$(-158)
-
$
20: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$744
Cost:
$1,058
$744 11,768 - - - - - - $744
11,768
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$450,272
Cost:
$498,673
$335,458 5,309,567 $62,568 7,841 $56,732 9,567 $(-4,486) - $335,458
5,309,567
kWh
$62,568
7,841
kW-months/year
$56,732
9,567
MMBtu
$(-4,486)
-
$
TOTAL IMPLEMENTED Savings:
$151,122
Cost:
$193,097
$123,157 1,949,302 $23,064 2,903 $9,387 1,583 $(-4,486) - $123,157
1,949,302
kWh
$23,064
2,903
kW-months/year
$9,387
1,583
MMBtu
$(-4,486)
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes