Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 2012
Principal Product plastic bottles and technology assistance
NAICS 325998 - All Other Miscellaneous Chemical Product and Preparation Manufacturing
SIC 2819 - Industrial Inorganic Chemicals, Nec
Sales $10,000,000-$50,000,000
# of Employees 68
Plant Area (Sq.Ft.) 43,000
Annual Production 100 Tons
Production Hrs. Annual 6,240
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $105,697 1,205,040 kWh $0.09
Electricity Demand $31,047 4,901 kW-months/year $6.33
Natural Gas $26,299 3,688 MMBtu $7.13
TOTAL ENERGY COSTS $163,043
RECOMMENDED SAVINGS* $24,471 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,924
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,725
Cost:
$9,258
$4,615 52,611 $1,110 175 - - $4,615
52,611
kWh
$1,110
175
kW-months/year
-
-
MMBtu
02: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$5,053
Cost:
$51,600
$360 4,102 $51 8 $4,642 651 $360
4,102
kWh
$51
8
kW-months/year
$4,642
651
MMBtu
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$3,859
Cost:
$16,925
$3,510 40,022 $349 55 - - $3,510
40,022
kWh
$349
55
kW-months/year
-
-
MMBtu
04: 2.2492 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR Savings:
$3,243
Cost:
$14,500
$231 2,637 $25 4 $2,987 419 $231
2,637
kWh
$25
4
kW-months/year
$2,987
419
MMBtu
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,979
Cost:
$1,826
$1,979 22,558 - - - - $1,979
22,558
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$1,968
Cost:
$10,438
- - - - $1,968 276 -
-
kWh
-
-
kW-months/year
$1,968
276
MMBtu
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,424
Cost:
$5,689
$1,189 13,557 $235 37 - - $1,189
13,557
kWh
$235
37
kW-months/year
-
-
MMBtu
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,103
Cost:
$1,000
$956 10,904 $147 23 - - $956
10,904
kWh
$147
23
kW-months/year
-
-
MMBtu
09: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$117
Cost:
$7
$104 1,186 $13 2 - - $104
1,186
kWh
$13
2
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$24,471
Cost:
$111,243
$12,944 147,577 $1,930 304 $9,597 1,346 $12,944
147,577
kWh
$1,930
304
kW-months/year
$9,597
1,346
MMBtu
TOTAL IMPLEMENTED Savings:
$8,924
Cost:
$12,091
$7,654 87,259 $1,270 200 - - $7,654
87,259
kWh
$1,270
200
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas