Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2015 |
Principal Product | Coated Steel Sheets |
NAICS | 332431 - Metal Can Manufacturing |
SIC | 3411 - Metal Cans |
Sales | $50,000,000-$100,000,000 |
# of Employees | 63 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 50,000 Tons |
Production Hrs. Annual | 6,912 |
Location (State) | WV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $159,385 | 4,649,432 | kWh | $0.03 |
Electricity Demand | $157,292 | 11,964 | kW-months/year | $13.15 |
Natural Gas | $653,004 | 121,846 | MMBtu | $5.36 |
TOTAL ENERGY COSTS | $969,681 | |||
RECOMMENDED SAVINGS* | $251,110 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $14,211 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $227,708 Cost: $366,480 |
$(-7,457) | (-217,404) | $(-4,958) | (-377) | $240,123 | 44,799 | - | - |
$(-7,457) (-217,404) kWh |
$(-4,958) (-377) kW-months/year |
$240,123 44,799 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $8,331 Cost: - |
$5,004 | 145,877 | $3,327 | 253 | - | - | - | - |
$5,004 145,877 kWh |
$3,327 253 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $6,021 Cost: $1,000 |
$4,484 | 130,720 | $2,985 | 227 | - | - | $(-1,448) | - |
$4,484 130,720 kWh |
$2,985 227 kW-months/year |
- - MMBtu |
$(-1,448) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,146 Cost: $3,449 |
$1,857 | 54,139 | $1,289 | 98 | - | - | - | - |
$1,857 54,139 kWh |
$1,289 98 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $2,835 Cost: $885 |
- | - | - | - | $2,835 | 529 | - | - |
- - kWh |
- - kW-months/year |
$2,835 529 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $1,057 Cost: $4,884 |
$636 | 18,544 | $421 | 32 | - | - | - | - |
$636 18,544 kWh |
$421 32 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $860 Cost: $39 |
$518 | 15,095 | $342 | 26 | - | - | - | - |
$518 15,095 kWh |
$342 26 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $599 Cost: $182 |
$362 | 10,541 | $237 | 18 | - | - | - | - |
$362 10,541 kWh |
$237 18 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $553 Cost: $634 |
$883 | 25,737 | $592 | 45 | - | - | $(-922) | - |
$883 25,737 kWh |
$592 45 kW-months/year |
- - MMBtu |
$(-922) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $251,110 Cost: $377,553 |
$6,287 | 183,249 | $4,235 | 322 | $242,958 | 45,328 | $(-2,370) | - | $6,287 183,249 kWh |
$4,235 322 kW-months/year |
$242,958 45,328 MMBtu |
$(-2,370) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $14,211 Cost: $11,034 |
$8,222 | 239,681 | $5,524 | 420 | $2,835 | 529 | $(-2,370) | - | $8,222 239,681 kWh |
$5,524 420 kW-months/year |
$2,835 529 MMBtu |
$(-2,370) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |