Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2016 |
Principal Product | Lumber |
NAICS | 321113 - Sawmills |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $10,000,000-$50,000,000 |
# of Employees | 126 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 18,000 Thousand Feet |
Production Hrs. Annual | 2,678 |
Location (State) | WV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $314,377 | 9,466,174 | kWh | $0.03 |
Electricity Demand | $432,504 | 28,229 | kW-months/year | $15.32 |
Wood | $91,250 | 58,400 | MMBtu | $1.56 |
TOTAL ENERGY COSTS | $838,131 | |||
RECOMMENDED SAVINGS* | $57,510 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $31,142 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Wood | Personnel Changes | Electricity Usage | Electricity Demand | Wood | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1116 IMPROVE COMBUSTION CONTROL CAPABILITY |
Savings: $22,825 Cost: $54,000 |
- | - | - | - | $22,825 | 14,608 | - | - |
- - kWh |
- - kW-months/year |
$22,825 14,608 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $7,474 Cost: $1,000 |
$6,716 | 202,293 | $4,351 | 284 | - | - | $(-3,593) | - |
$6,716 202,293 kWh |
$4,351 284 kW-months/year |
- - MMBtu |
$(-3,593) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $14,320 Cost: - |
$4,668 | 140,589 | $9,652 | 630 | - | - | - | - |
$4,668 140,589 kWh |
$9,652 630 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $5,859 Cost: $1,478 |
$1,988 | 59,890 | $4,351 | 284 | - | - | $(-480) | - |
$1,988 59,890 kWh |
$4,351 284 kW-months/year |
- - MMBtu |
$(-480) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $2,584 Cost: $5,000 |
$2,584 | 77,845 | - | - | - | - | - | - |
$2,584 77,845 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,573 Cost: $450 |
$439 | 13,231 | $1,134 | 74 | - | - | - | - |
$439 13,231 kWh |
$1,134 74 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,069 Cost: $260 |
$1,069 | 33,207 | - | - | - | - | - | - |
$1,069 33,207 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $959 Cost: $1,940 |
- | - | - | - | $959 | 615 | - | - |
- - kWh |
- - kW-months/year |
$959 615 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $847 Cost: $60 |
$265 | 7,984 | $582 | 38 | - | - | - | - |
$265 7,984 kWh |
$582 38 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $57,510 Cost: $64,188 |
$17,729 | 535,039 | $20,070 | 1,310 | $23,784 | 15,223 | $(-4,073) | - | $17,729 535,039 kWh |
$20,070 1,310 kW-months/year |
$23,784 15,223 MMBtu |
$(-4,073) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $31,142 Cost: $3,248 |
$15,145 | 457,194 | $20,070 | 1,310 | - | - | $(-4,073) | - | $15,145 457,194 kWh |
$20,070 1,310 kW-months/year |
- - MMBtu |
$(-4,073) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Wood | Personnel Changes | Electricity Usage | Electricity Demand | Wood | Personnel Changes |