Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2016 |
Principal Product | Purchased Glass |
NAICS | 327215 - Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231 - Products Of Purchased Glass |
Sales | $100,000,000-$500,000,000 |
# of Employees | 500 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 1,000,000 Pieces |
Production Hrs. Annual | 5,100 |
Location (State) | WV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $337,521 | 8,828,952 | kWh | $0.04 |
Electricity Demand | $342,804 | 22,375 | kW-months/year | $15.32 |
Natural Gas | $14,632 | 2,208 | MMBtu | $6.63 |
TOTAL ENERGY COSTS | $694,957 | |||
RECOMMENDED SAVINGS* | $52,794 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $42,010 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $30,329 Cost: $30,168 |
$15,606 | 408,525 | $14,723 | 961 | - | - | - | - |
$15,606 408,525 kWh |
$14,723 961 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $5,145 Cost: $3,264 |
- | - | - | - | $5,145 | 776 | - | - |
- - kWh |
- - kW-months/year |
$5,145 776 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $4,286 Cost: $65 |
$2,202 | 57,650 | $2,084 | 136 | - | - | - | - |
$2,202 57,650 kWh |
$2,084 136 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,003 Cost: $305 |
$1,548 | 40,519 | $1,455 | 95 | - | - | - | - |
$1,548 40,519 kWh |
$1,455 95 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6232 INSTALL SET-BACK TIMERS |
Savings: $2,321 Cost: $3,148 |
- | - | - | - | $2,321 | 350 | - | - |
- - kWh |
- - kW-months/year |
$2,321 350 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,139 Cost: $10,151 |
$867 | 22,706 | $1,272 | 83 | - | - | - | - |
$867 22,706 kWh |
$1,272 83 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $1,984 Cost: $1,080 |
$1,155 | 30,229 | $1,088 | 71 | - | - | $(-259) | - |
$1,155 30,229 kWh |
$1,088 71 kW-months/year |
- - MMBtu |
$(-259) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,870 Cost: $756 |
- | - | - | - | $1,870 | 282 | - | - |
- - kWh |
- - kW-months/year |
$1,870 282 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,448 Cost: $1,208 |
$743 | 19,453 | $705 | 46 | - | - | - | - |
$743 19,453 kWh |
$705 46 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $269 Cost: $370 |
$269 | 7,032 | - | - | - | - | - | - |
$269 7,032 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $52,794 Cost: $50,515 |
$22,390 | 586,114 | $21,327 | 1,392 | $9,336 | 1,408 | $(-259) | - | $22,390 586,114 kWh |
$21,327 1,392 kW-months/year |
$9,336 1,408 MMBtu |
$(-259) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $42,010 Cost: $42,139 |
$21,647 | 566,661 | $20,622 | 1,346 | - | - | $(-259) | - | $21,647 566,661 kWh |
$20,622 1,346 kW-months/year |
- - MMBtu |
$(-259) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |