Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2017 |
Principal Product | hardwood flooring |
NAICS | 321918 - Other Millwork (including Flooring) |
SIC | 2426 - Hardwood Dimension & Flooring Mills |
Sales | $10,000,000-$50,000,000 |
# of Employees | 81 |
Plant Area (Sq.Ft.) | 116,417 |
Annual Production | 2,900 Thousand Feet |
Production Hrs. Annual | 2,000 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $203,233 | 2,643,539 | kWh | $0.08 |
Electricity Demand | $79,439 | 14,314 | kW-months/year | $5.55 |
Electricity Fees | $3,362 | - | $ | - |
Natural Gas | $30,940 | 14,691 | MMBtu | $2.11 |
TOTAL ENERGY COSTS | $320,437 | |||
RECOMMENDED SAVINGS* | $48,250 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $23,388 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $9,343 Cost: $2,478 |
- | - | - | - | $9,343 | 4,428 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$9,343 4,428 MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,922 Cost: $41,392 |
$6,225 | 80,955 | $2,697 | 486 | - | - | - | - | - | - | - | - |
$6,225 80,955 kWh |
$2,697 486 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.642 INSTALL SENSORS TO DETECT AND AVOID JAMS |
Savings: $6,579 Cost: $1,611 |
$5,985 | 77,834 | $594 | 107 | - | - | - | - | - | - | - | - |
$5,985 77,834 kWh |
$594 107 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $6,331 Cost: - |
$4,416 | 57,420 | $1,915 | 345 | - | - | - | - | - | - | - | - |
$4,416 57,420 kWh |
$1,915 345 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4151 MINIMIZE WATER USAGE |
Savings: $4,164 Cost: $750 |
- | - | - | - | - | - | $1,218 | 71 | $3,463 | 71 | $(-517) | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,218 71 Tgal |
$3,463 71 Tgal |
$(-517) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $3,443 Cost: $1,000 |
$3,657 | 47,555 | $1,582 | 285 | - | - | - | - | - | - | $(-1,796) | - |
$3,657 47,555 kWh |
$1,582 285 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
$(-1,796) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,545 Cost: $8,388 |
$2,195 | 28,541 | $350 | 63 | - | - | - | - | - | - | - | - |
$2,195 28,541 kWh |
$350 63 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $2,479 Cost: $10,000 |
$1,730 | 22,502 | $749 | 135 | - | - | - | - | - | - | - | - |
$1,730 22,502 kWh |
$749 135 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $1,157 Cost: $3,278 |
$807 | 10,500 | $350 | 63 | - | - | - | - | - | - | - | - |
$807 10,500 kWh |
$350 63 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,140 Cost: $1,058 |
$796 | 10,350 | $344 | 62 | - | - | - | - | - | - | - | - |
$796 10,350 kWh |
$344 62 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $1,024 Cost: $699 |
$869 | 11,303 | $377 | 68 | - | - | - | - | - | - | $(-222) | - |
$869 11,303 kWh |
$377 68 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
$(-222) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $863 Cost: $431 |
$602 | 7,833 | $261 | 47 | - | - | - | - | - | - | - | - |
$602 7,833 kWh |
$261 47 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $260 Cost: $850 |
- | - | - | - | $260 | 123 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$260 123 MMBtu |
- - Tgal |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $48,250 Cost: $71,935 |
$27,282 | 354,793 | $9,219 | 1,661 | $9,603 | 4,551 | $1,218 | 71 | $3,463 | 71 | $(-2,535) | - | $27,282 354,793 kWh |
$9,219 1,661 kW-months/year |
$9,603 4,551 MMBtu |
$1,218 71 Tgal |
$3,463 71 Tgal |
$(-2,535) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $23,388 Cost: $52,760 |
$17,964 | 233,607 | $7,182 | 1,294 | $260 | 123 | - | - | - | - | $(-2,018) | - | $17,964 233,607 kWh |
$7,182 1,294 kW-months/year |
$260 123 MMBtu |
- - Tgal |
- - Tgal |
$(-2,018) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Administrative Changes |