Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2018 |
Principal Product | Snow removal equipment |
NAICS | 332999 - All Other Miscellaneous Fabricated Metal Product Manufacturing |
SIC | 3499 - Fabricated Metal Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 169 Thousand Feet |
Production Hrs. Annual | 3,120 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $367,559 | 3,280,758 | kWh | $0.11 |
Electricity Demand | $73,243 | 10,800 | kW-months/year | $6.78 |
Electricity Fees | $13,587 | - | $ | - |
Natural Gas | $85,834 | 15,575 | MMBtu | $5.51 |
TOTAL ENERGY COSTS | $575,309 | |||
RECOMMENDED SAVINGS* | $183,729 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $84,119 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $81,443 Cost: $80,480 |
$81,443 | 703,913 | - | - | - | - | - | - | - | - | - | - | - | - |
$81,443 703,913 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $77,310 Cost: $17,740 |
$63,115 | 545,504 | $14,195 | 2,094 | - | - | - | - | - | - | - | - | - | - |
$63,115 545,504 kWh |
$14,195 2,094 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $17,434 Cost: $68,000 |
$14,227 | 122,968 | $3,207 | 473 | - | - | - | - | - | - | - | - | - | - |
$14,227 122,968 kWh |
$3,207 473 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $2,854 Cost: $533 |
$2,392 | 20,672 | $542 | 80 | - | - | - | - | - | - | $(-80) | - | - | - |
$2,392 20,672 kWh |
$542 80 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
$(-80) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $2,441 Cost: $500 |
- | - | $2,441 | 360 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$2,441 360 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $810 Cost: $1,600 |
- | - | - | - | $810 | 147 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$810 147 MMBtu |
- - Tgal |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.3131 USE EVAPORATION TO CONCENTRATE MATERIAL |
Savings: $733 Cost: $1,750 |
- | - | - | - | - | - | $296 | 37 | $512 | 37 | - | - | $(-75) | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$296 37 Tgal |
$512 37 Tgal |
- - $ |
$(-75) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $704 Cost: $40 |
$575 | 4,970 | $129 | 19 | - | - | - | - | - | - | - | - | - | - |
$575 4,970 kWh |
$129 19 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $183,729 Cost: $170,643 |
$161,752 | 1,398,027 | $20,514 | 3,026 | $810 | 147 | $296 | 37 | $512 | 37 | $(-80) | - | $(-75) | - | $161,752 1,398,027 kWh |
$20,514 3,026 kW-months/year |
$810 147 MMBtu |
$296 37 Tgal |
$512 37 Tgal |
$(-80) - $ |
$(-75) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $84,119 Cost: $20,413 |
$66,082 | 571,146 | $17,307 | 2,553 | $810 | 147 | - | - | - | - | $(-80) | - | - | - | $66,082 571,146 kWh |
$17,307 2,553 kW-months/year |
$810 147 MMBtu |
- - Tgal |
- - Tgal |
$(-80) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | Water Disposal | Personnel Changes | Administrative Changes |