Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2019 |
Principal Product | Glass display panels |
NAICS | 327215 - Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231 - Products Of Purchased Glass |
Sales | $5,000,000-$10,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 90,000 |
Annual Production | 12,000,000 Units |
Production Hrs. Annual | 2,500 |
Location (State) | WV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $65,084 | 1,846,290 | kWh | $0.04 |
Electricity Demand | $125,662 | 7,110 | kW-months/year | $17.67 |
Electricity Fees | $604 | - | $ | - |
Natural Gas | $70,480 | 9,137 | MMBtu | $7.71 |
TOTAL ENERGY COSTS | $261,830 | |||
RECOMMENDED SAVINGS* | $27,092 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $10,810 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1212 OPERATE BOILERS ON HIGH FIRE SETTING |
Savings: $14,618 Cost: $15,000 |
- | - | - | - | $14,618 | 1,896 | - | - |
- - kWh |
- - kW-months/year |
$14,618 1,896 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $7,189 Cost: $3,000 |
- | - | - | - | $7,209 | 935 | $(-20) | - |
- - kWh |
- - kW-months/year |
$7,209 935 MMBtu |
$(-20) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,785 Cost: $3,399 |
$513 | 14,537 | $1,272 | 72 | - | - | - | - |
$513 14,537 kWh |
$1,272 72 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $1,129 Cost: $1,000 |
$1,129 | 31,974 | - | - | - | - | - | - |
$1,129 31,974 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,078 Cost: $910 |
$318 | 9,008 | $760 | 43 | - | - | - | - |
$318 9,008 kWh |
$760 43 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $535 Cost: $3,000 |
$535 | 15,142 | - | - | - | - | - | - |
$535 15,142 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $523 Cost: $471 |
$223 | 6,307 | $300 | 17 | - | - | - | - |
$223 6,307 kWh |
$300 17 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $120 Cost: $533 |
$103 | 2,911 | $177 | 10 | - | - | $(-160) | - |
$103 2,911 kWh |
$177 10 kW-months/year |
- - MMBtu |
$(-160) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $115 Cost: - |
$44 | 1,252 | $71 | 4 | - | - | - | - |
$44 1,252 kWh |
$71 4 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $27,092 Cost: $27,313 |
$2,865 | 81,131 | $2,580 | 146 | $21,827 | 2,831 | $(-180) | - | $2,865 81,131 kWh |
$2,580 146 kW-months/year |
$21,827 2,831 MMBtu |
$(-180) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $10,810 Cost: $8,313 |
$1,201 | 34,015 | $2,580 | 146 | $7,209 | 935 | $(-180) | - | $1,201 34,015 kWh |
$2,580 146 kW-months/year |
$7,209 935 MMBtu |
$(-180) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |