IAC Center | West Virginia University |
---|---|
Assessment Year | 2020 |
Principal Product | Water treatment |
NAICS | 221310 - Water Supply and Irrigation Systems |
SIC | 4941 - Water Supply |
Sales | $10,000,000-$50,000,000 |
# of Employees | 16 |
Plant Area (Sq.Ft.) | 65,000 |
Annual Production | 4,000,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | WV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $301,797 | 7,962,632 | kWh | $0.04 |
Electricity Demand | $248,895 | 13,971 | kW-months/year | $17.82 |
Electricity Fees | $17,473 | - | $ | - |
Natural Gas | $17,519 | 2,215 | MMBtu | $7.91 |
TOTAL ENERGY COSTS | $585,684 | |||
RECOMMENDED SAVINGS* | $28,046 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $13,594 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Electricity Usage | Electricity Demand | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,179 Cost: $22,995 |
$6,174 | 162,898 | $5,005 | 281 | - | - |
$6,174 162,898 kWh |
$5,005 281 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $9,425 Cost: $9,350 |
$5,738 | 151,400 | $3,687 | 207 | - | - |
$5,738 151,400 kWh |
$3,687 207 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $5,027 Cost: $10,000 |
$5,027 | 132,631 | - | - | - | - |
$5,027 132,631 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,724 Cost: - |
$1,047 | 27,632 | $677 | 38 | - | - |
$1,047 27,632 kWh |
$677 38 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $691 Cost: $651 |
$1,131 | 29,852 | - | - | $(-440) | - |
$1,131 29,852 kWh |
- - kW-months/year |
$(-440) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $28,046 Cost: $42,996 |
$19,117 | 504,413 | $9,369 | 526 | $(-440) | - | $19,117 504,413 kWh |
$9,369 526 kW-months/year |
$(-440) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $13,594 Cost: $23,646 |
$8,352 | 220,382 | $5,682 | 319 | $(-440) | - | $8,352 220,382 kWh |
$5,682 319 kW-months/year |
$(-440) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Electricity Usage | Electricity Demand | Personnel Changes |