Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2020 |
Principal Product | Cab trim |
NAICS | 336390 - Other Motor Vehicle Parts Manufacturing |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $50,000,000-$100,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 129,000 |
Annual Production | 6,000,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $294,660 | 4,539,200 | kWh | $0.06 |
Electricity Demand | $152,299 | 11,929 | kW-months/year | $12.77 |
Electricity Fees | $6,562 | - | $ | - |
TOTAL ENERGY COSTS | $456,901 | |||
RECOMMENDED SAVINGS* | $165,142 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $68,319 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Personnel Changes | Water Consumption | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Personnel Changes | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $42,278 Cost: $44,000 |
$42,278 | 651,439 | - | - | - | - | - | - | - | - | - | - |
$42,278 651,439 kWh |
- - kW-months/year |
- - $ |
- - lb |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $41,451 Cost: $66,168 |
$32,652 | 503,105 | $8,799 | 689 | - | - | - | - | - | - | - | - |
$32,652 503,105 kWh |
$8,799 689 kW-months/year |
- - $ |
- - lb |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $24,406 Cost: $31,200 |
$24,406 | 376,051 | - | - | - | - | - | - | - | - | - | - |
$24,406 376,051 kWh |
- - kW-months/year |
- - $ |
- - lb |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $16,468 Cost: $5,109 |
$12,969 | 199,845 | $3,499 | 274 | - | - | - | - | - | - | - | - |
$12,969 199,845 kWh |
$3,499 274 kW-months/year |
- - $ |
- - lb |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $13,855 Cost: $12,500 |
- | - | - | - | - | - | $13,855 | 422,400 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$13,855 422,400 lb |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $9,428 Cost: $15,500 |
$7,423 | 114,378 | $2,005 | 157 | - | - | - | - | - | - | - | - |
$7,423 114,378 kWh |
$2,005 157 kW-months/year |
- - $ |
- - lb |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,881 Cost: $1,468 |
$3,847 | 59,272 | $1,034 | 81 | - | - | - | - | - | - | - | - |
$3,847 59,272 kWh |
$1,034 81 kW-months/year |
- - $ |
- - lb |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5131 RECYCLE WHITE WATER |
Savings: $3,957 Cost: $8,600 |
$(-232) | (-3,581) | - | - | - | - | - | - | - | - | $4,189 | - |
$(-232) (-3,581) kWh |
- - kW-months/year |
- - $ |
- - lb |
- - $ |
$4,189 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,957 Cost: $813 |
$2,331 | 35,916 | $626 | 49 | - | - | - | - | - | - | - | - |
$2,331 35,916 kWh |
$626 49 kW-months/year |
- - $ |
- - lb |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,899 Cost: $8,000 |
- | - | - | - | $2,899 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,899 - $ |
- - lb |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,693 Cost: $1,000 |
$1,693 | 26,090 | - | - | - | - | - | - | - | - | - | - |
$1,693 26,090 kWh |
- - kW-months/year |
- - $ |
- - lb |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $768 Cost: $100 |
$602 | 9,276 | $166 | 13 | - | - | - | - | - | - | - | - |
$602 9,276 kWh |
$166 13 kW-months/year |
- - $ |
- - lb |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $101 Cost: $271 |
$251 | 3,873 | - | - | - | - | - | - | $(-150) | - | - | - |
$251 3,873 kWh |
- - kW-months/year |
- - $ |
- - lb |
$(-150) - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $165,142 Cost: $194,729 |
$128,220 | 1,975,664 | $16,129 | 1,263 | $2,899 | - | $13,855 | 422,400 | $(-150) | - | $4,189 | - | $128,220 1,975,664 kWh |
$16,129 1,263 kW-months/year |
$2,899 - $ |
$13,855 422,400 lb |
$(-150) - $ |
$4,189 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $68,319 Cost: $74,929 |
$54,345 | 837,377 | $14,124 | 1,106 | - | - | - | - | $(-150) | - | - | - | $54,345 837,377 kWh |
$14,124 1,106 kW-months/year |
- - $ |
- - lb |
$(-150) - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Personnel Changes | Water Consumption | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Personnel Changes | Water Consumption |