IAC logo
IAC Assessment: WV0625
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WV0625
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 2022
Principal Product Outdoor Sporting Goods Distribution
NAICS 493110 - General Warehousing and Storage
SIC 4225 - General Warehousing And Storage
Sales $50,000,000-$100,000,000
# of Employees 425
Plant Area (Sq.Ft.) 1,167,604
Annual Production 20,000,000 Units
Production Hrs. Annual 8,760
Location (State) WV
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $316,606 5,685,300 kWh $0.06
Electricity Demand $155,222 9,379 kW-months/year $16.55
Electricity Fees $2,388 - $ -
Natural Gas $54,599 23,894 MMBtu $2.29
TOTAL ENERGY COSTS $528,815
RECOMMENDED SAVINGS* $129,124 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $83,521
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$73,145
Cost:
$29,680
$51,978 933,169 $21,167 1,279 - - - - $51,978
933,169
kWh
$21,167
1,279
kW-months/year
-
-
MMBtu
-
-
$
02: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$28,641
Cost:
$112,444
$(-6,489) (-116,492) $(-2,648) (-160) $37,778 16,497 - - $(-6,489)
(-116,492)
kWh
$(-2,648)
(-160)
kW-months/year
$37,778
16,497
MMBtu
-
-
$
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$12,687
Cost:
$17,469
$7,523 135,067 $5,164 312 - - - - $7,523
135,067
kWh
$5,164
312
kW-months/year
-
-
MMBtu
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$6,879
Cost:
$893
$4,893 87,843 $1,986 120 - - - - $4,893
87,843
kWh
$1,986
120
kW-months/year
-
-
MMBtu
-
-
$
05: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$3,011
Cost:
$6,065
$2,035 36,543 $976 59 - - - - $2,035
36,543
kWh
$976
59
kW-months/year
-
-
MMBtu
-
-
$
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,547
Cost:
$2,323
$485 8,703 $199 12 $863 377 - - $485
8,703
kWh
$199
12
kW-months/year
$863
377
MMBtu
-
-
$
07: 2.2515 USE OPTIMUM THICKNESS INSULATION Savings:
$1,264
Cost:
$5,280
- - - - $1,264 552 - - -
-
kWh
-
-
kW-months/year
$1,264
552
MMBtu
-
-
$
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$997
Cost:
$120
$716 12,860 $281 17 - - - - $716
12,860
kWh
$281
17
kW-months/year
-
-
MMBtu
-
-
$
09: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$734
Cost:
$323
$519 9,317 $215 13 - - - - $519
9,317
kWh
$215
13
kW-months/year
-
-
MMBtu
-
-
$
10: 2.4151 DEVELOP A REPAIR/REPLACE POLICY Savings:
$219
Cost:
$1,027
$287 5,144 $116 7 - - $(-184) - $287
5,144
kWh
$116
7
kW-months/year
-
-
MMBtu
$(-184)
-
$
TOTAL RECOMMENDED Savings:
$129,124
Cost:
$175,624
$61,947 1,112,154 $27,456 1,659 $39,905 17,426 $(-184) - $61,947
1,112,154
kWh
$27,456
1,659
kW-months/year
$39,905
17,426
MMBtu
$(-184)
-
$
TOTAL IMPLEMENTED Savings:
$83,521
Cost:
$34,366
$58,878 1,057,036 $23,964 1,448 $863 377 $(-184) - $58,878
1,057,036
kWh
$23,964
1,448
kW-months/year
$863
377
MMBtu
$(-184)
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes