Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2022 |
Principal Product | Wood cabinets, casework |
NAICS | 321999 - All Other Miscellaneous Wood Product Manufacturing |
SIC | 2499 - Wood Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 48 |
Plant Area (Sq.Ft.) | 47,230 |
Annual Production | 25,000 Units |
Production Hrs. Annual | 4,000 |
Location (State) | WV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $63,749 | 1,493,992 | kWh | $0.04 |
Electricity Demand | $60,350 | 4,149 | kW-months/year | $14.55 |
Electricity Fees | $129,466 | - | $ | - |
Natural Gas | $6,080 | 667 | MMBtu | $9.12 |
TOTAL ENERGY COSTS | $259,645 | |||
RECOMMENDED SAVINGS* | $19,550 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,399 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $7,261 Cost: $14,000 |
$4,592 | 100,701 | - | - | $2,669 | 293 | - | - |
$4,592 100,701 kWh |
- - kW-months/year |
$2,669 293 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,860 Cost: $7,799 |
$1,823 | 39,983 | $2,037 | 140 | - | - | - | - |
$1,823 39,983 kWh |
$2,037 140 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,701 Cost: $160 |
$1,377 | 30,198 | $1,324 | 91 | - | - | - | - |
$1,377 30,198 kWh |
$1,324 91 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT |
Savings: $2,566 Cost: $12,480 |
$(-1,768) | (-38,774) | $(-1,688) | (-116) | $6,022 | 661 | - | - |
$(-1,768) (-38,774) kWh |
$(-1,688) (-116) kW-months/year |
$6,022 661 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $1,324 Cost: $3,185 |
$422 | 9,253 | $902 | 62 | - | - | - | - |
$422 9,253 kWh |
$902 62 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $792 Cost: $3,586 |
$792 | 17,370 | - | - | - | - | - | - |
$792 17,370 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $454 Cost: $467 |
$236 | 5,165 | $218 | 15 | - | - | - | - |
$236 5,165 kWh |
$218 15 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $301 Cost: $40 |
$155 | 3,407 | $146 | 10 | - | - | - | - |
$155 3,407 kWh |
$146 10 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $291 Cost: $1,347 |
$207 | 4,529 | $204 | 14 | - | - | $(-120) | - |
$207 4,529 kWh |
$204 14 kW-months/year |
- - MMBtu |
$(-120) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $19,550 Cost: $43,064 |
$7,836 | 171,832 | $3,143 | 216 | $8,691 | 954 | $(-120) | - | $7,836 171,832 kWh |
$3,143 216 kW-months/year |
$8,691 954 MMBtu |
$(-120) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,399 Cost: $13,399 |
$4,590 | 100,652 | $3,929 | 270 | - | - | $(-120) | - | $4,590 100,652 kWh |
$3,929 270 kW-months/year |
- - MMBtu |
$(-120) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||