Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2022 |
Principal Product | Wastewater Treatment |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $50,000,000-$100,000,000 |
# of Employees | 30 |
Plant Area (Sq.Ft.) | 290,000 |
Annual Production | 3,630,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | MD |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $262,718 | 4,299,254 | kWh | $0.06 |
Electricity Demand | $42,388 | 17,231 | kW-months/year | $2.46 |
Electricity Fees | $10,297 | - | $ | - |
Fuel Oil #2 | $9,200 | 301 | MMBtu | $30.56 |
TOTAL ENERGY COSTS | $324,603 | |||
RECOMMENDED SAVINGS* | $69,318 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,235 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #2 | Personnel Changes | Electricity Usage | Electricity Demand | Fuel Oil #2 | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.5195 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS |
Savings: $45,174 Cost: $141,500 |
$42,812 | 700,694 | $2,362 | 960 | - | - | - | - |
$42,812 700,694 kWh |
$2,362 960 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $12,909 Cost: $43,000 |
$12,235 | 200,244 | $674 | 274 | - | - | - | - |
$12,235 200,244 kWh |
$674 274 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $8,882 Cost: $8,985 |
$8,417 | 137,764 | $465 | 189 | - | - | - | - |
$8,417 137,764 kWh |
$465 189 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $1,166 Cost: $1,633 |
$1,247 | 20,413 | $69 | 28 | - | - | $(-150) | - |
$1,247 20,413 kWh |
$69 28 kW-months/year |
- - MMBtu |
$(-150) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $973 Cost: $1,500 |
$2,217 | 36,290 | $123 | 50 | - | - | $(-1,367) | - |
$2,217 36,290 kWh |
$123 50 kW-months/year |
- - MMBtu |
$(-1,367) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $214 Cost: $908 |
- | - | - | - | $214 | 7 | - | - |
- - kWh |
- - kW-months/year |
$214 7 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $69,318 Cost: $197,526 |
$66,928 | 1,095,405 | $3,693 | 1,501 | $214 | 7 | $(-1,517) | - | $66,928 1,095,405 kWh |
$3,693 1,501 kW-months/year |
$214 7 MMBtu |
$(-1,517) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,235 Cost: $13,026 |
$11,881 | 194,467 | $657 | 267 | $214 | 7 | $(-1,517) | - | $11,881 194,467 kWh |
$657 267 kW-months/year |
$214 7 MMBtu |
$(-1,517) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #2 | Personnel Changes | Electricity Usage | Electricity Demand | Fuel Oil #2 | Personnel Changes |