Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2024 |
Principal Product | Vibrating (Shaker) Screens |
NAICS | 333131 - Mining Machinery and Equipment Manufacturing |
SIC | 3532 - Mining Machinery |
Sales | $50,000,000-$100,000,000 |
# of Employees | 291 |
Plant Area (Sq.Ft.) | 274,491 |
Annual Production | 800,000 Units |
Production Hrs. Annual | 5,200 |
Location (State) | WV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $276,879 | 3,834,860 | kWh | $0.07 |
Electricity Demand | $86,898 | 10,050 | kW-months/year | $8.65 |
Natural Gas | $91,502 | 7,716 | MMBtu | $11.86 |
TOTAL ENERGY COSTS | $455,279 | |||
RECOMMENDED SAVINGS* | $81,999 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $39,114 Cost: $61,425 |
$30,642 | 424,040 | $8,472 | 979 | - | - | - | - |
$30,642 424,040 kWh |
$8,472 979 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $15,802 Cost: $77,610 |
$15,802 | 218,871 | - | - | - | - | - | - |
$15,802 218,871 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $10,770 Cost: $43,200 |
$8,434 | 116,813 | $2,336 | 270 | - | - | - | - |
$8,434 116,813 kWh |
$2,336 270 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $8,001 Cost: $13,171 |
$4,948 | 68,534 | $3,053 | 353 | - | - | - | - |
$4,948 68,534 kWh |
$3,053 353 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,506 Cost: $770 |
$1,961 | 27,154 | $545 | 63 | - | - | - | - |
$1,961 27,154 kWh |
$545 63 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $1,691 Cost: $8,244 |
$1,172 | 16,232 | $519 | 60 | - | - | - | - |
$1,172 16,232 kWh |
$519 60 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,211 Cost: $1,154 |
$951 | 13,174 | $260 | 30 | - | - | - | - |
$951 13,174 kWh |
$260 30 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $1,123 Cost: $1,296 |
$1,230 | 17,034 | $337 | 39 | - | - | $(-444) | - |
$1,230 17,034 kWh |
$337 39 kW-months/year |
- - MMBtu |
$(-444) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $878 Cost: $581 |
- | - | - | - | $878 | 74 | - | - |
- - kWh |
- - kW-months/year |
$878 74 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $666 Cost: $148 |
$519 | 7,188 | $147 | 17 | - | - | - | - |
$519 7,188 kWh |
$147 17 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $237 Cost: $1,029 |
- | - | - | - | $237 | 20 | - | - |
- - kWh |
- - kW-months/year |
$237 20 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $81,999 Cost: $208,628 |
$65,659 | 909,040 | $15,669 | 1,811 | $1,115 | 94 | $(-444) | - | $65,659 909,040 kWh |
$15,669 1,811 kW-months/year |
$1,115 94 MMBtu |
$(-444) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |