Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2025 |
Principal Product | Offering Envelops and Paper Goods |
NAICS | 322230 - Stationery Product Manufacturing |
SIC | 2677 - Envelopes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 72,000 |
Annual Production | 200,000,000 Units |
Production Hrs. Annual | 4,160 |
Location (State) | WV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $57,121 | 879,709 | kWh | $0.06 |
Electricity Demand | $52,483 | 3,080 | kW-months/year | $17.04 |
Electricity Fees | $4,645 | - | $ | - |
Fuel Oil #1 | $41,379 | 1,807 | MMBtu | $22.90 |
TOTAL ENERGY COSTS | $157,215 | |||
RECOMMENDED SAVINGS* | $21,421 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #1 | Personnel Changes | Electricity Usage | Electricity Demand | Fuel Oil #1 | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER |
Savings: $11,496 Cost: $6,800 |
- | - | - | - | $11,496 | 502 | - | - |
- - kWh |
- - kW-months/year |
$11,496 502 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,726 Cost: $1,870 |
$1,550 | 23,890 | $1,176 | 69 | - | - | - | - |
$1,550 23,890 kWh |
$1,176 69 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $2,689 Cost: $3,615 |
- | - | - | - | $2,689 | 118 | - | - |
- - kWh |
- - kW-months/year |
$2,689 118 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,592 Cost: $7,384 |
$1,432 | 22,067 | $1,160 | 68 | - | - | - | - |
$1,432 22,067 kWh |
$1,160 68 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $898 Cost: $3,200 |
$1,118 | 17,223 | $852 | 50 | - | - | $(-1,072) | - |
$1,118 17,223 kWh |
$852 50 kW-months/year |
- - MMBtu |
$(-1,072) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $828 Cost: $937 |
$521 | 8,029 | $307 | 18 | - | - | - | - |
$521 8,029 kWh |
$307 18 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $192 Cost: $572 |
$107 | 1,644 | $85 | 5 | - | - | - | - |
$107 1,644 kWh |
$85 5 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $21,421 Cost: $24,378 |
$4,728 | 72,853 | $3,580 | 210 | $14,185 | 620 | $(-1,072) | - | $4,728 72,853 kWh |
$3,580 210 kW-months/year |
$14,185 620 MMBtu |
$(-1,072) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #1 | Personnel Changes | Electricity Usage | Electricity Demand | Fuel Oil #1 | Personnel Changes |