Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
31
matching recommendationsNAICS | 2213 | Water, Sewage and Other Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0391 # 09 Y:2010 | 09 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $17,506 | $328,173 | Not Implemented |
SF0391 # 04 Y:2010 | 04 | 2010 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $128,228 | $381,609 | Not Implemented |
SF0391 # 03 Y:2010 | 03 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $14,943 | $11,249 | Implemented |
SF0391 # 02 Y:2010 | 02 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $26,321 | $16,124 | Not Implemented |
SF0391 # 01 Y:2010 | 01 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,075 | $0 | Not Implemented |
SF0391 # 07 Y:2010 | 07 | 2010 | INSTALL OCCUPANCY SENSORS | $4,484 | $17,522 | Implemented |
SF0391 # 08 Y:2010 | 08 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $27,181 | $174,884 | Not Implemented |
SF0391 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,635 | $40,292 | Implemented |
SF0391 # 05 Y:2010 | 05 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $25,418 | $81,160 | Not Implemented |
SF0389 # 05 Y:2010 | 05 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,157 | $2,712 | Implemented |
SF0389 # 11 Y:2010 | 11 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $812 | $7,156 | Implemented |
SF0389 # 10 Y:2010 | 10 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,037 | $9,053 | Implemented |
SF0389 # 09 Y:2010 | 09 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,274 | $8,179 | Implemented |
SF0389 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,881 | $9,823 | Implemented |
SF0389 # 07 Y:2010 | 07 | 2010 | USE PHOTOCELL CONTROLS | $11,135 | $19,068 | Implemented |
SF0389 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $4,881 | $7,273 | Implemented |
SF0389 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $953 | $672 | Implemented |
SF0389 # 03 Y:2010 | 03 | 2010 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $6,873 | $2,392 | Implemented |
SF0389 # 02 Y:2010 | 02 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $255 | $31 | Implemented |
SF0389 # 01 Y:2010 | 01 | 2010 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $10,049 | $400 | Implemented |
SD0428 # 01 Y:2010 | 01 | 2010 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,812 | $400 | Implemented |
SD0428 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $265 | $777 | Not Implemented |
SD0428 # 05 Y:2010 | 05 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,796 | $15,635 | Not Implemented |
SD0428 # 04 Y:2010 | 04 | 2010 | INCREASE USE OF AUTOMATION | $3,390 | $6,200 | Not Implemented |
SD0428 # 03 Y:2010 | 03 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,585 | $11,320 | Not Implemented |