Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15
matching recommendationsNAICS | 221320 | Sewage Treatment Facilities |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IP0143 # 01 Y:2020 | 01 | 2020 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $233 | $0 | Implemented |
IP0143 # 02 Y:2020 | 02 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,901 | $48 | Implemented |
IP0143 # 04 Y:2020 | 04 | 2020 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,298 | $420 | Implemented |
IP0143 # 07 Y:2020 | 07 | 2020 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,059 | $1,227 | Implemented |
IP0143 # 09 Y:2020 | 09 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,338 | $16,716 | Implemented |
IP0115 # 01 Y:2019 | 01 | 2019 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $1,898 | $1,950 | Implemented |
IP0115 # 02 Y:2019 | 02 | 2019 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $188 | $500 | Implemented |
IP0115 # 03 Y:2019 | 03 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,936 | $6,650 | Implemented |
IP0089 # 01 Y:2017 | 01 | 2017 | REUSE RICH WHITE WATER IN OTHER APPLICATIONS | $21,884 | $224 | Implemented |
IP0089 # 03 Y:2017 | 03 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,654 | $396 | Implemented |
IP0089 # 05 Y:2017 | 05 | 2017 | INSTALL OCCUPANCY SENSORS | $1,298 | $1,953 | Implemented |
IP0089 # 07 Y:2017 | 07 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,789 | $11,754 | Implemented |
IP0089 # 10 Y:2017 | 10 | 2017 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $1,079 | $5,047 | Implemented |
IP0038 # 01 Y:2015 | 01 | 2015 | INSTALL TIMERS AND/OR THERMOSTATS | $6,356 | $73 | Implemented |
IP0038 # 08 Y:2015 | 08 | 2015 | INSTALL OCCUPANCY SENSORS | $123 | $400 | Implemented |