Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
91
matching recommendationsNAICS | 311 | Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0841 # 05 Y:2022 | 05 | 2022 | USE HEAT PUMP FOR SPACE CONDITIONING | $2,033 | $7,500 | Not Implemented |
MA0841 # 01 Y:2022 | 01 | 2022 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $11,138 | $8,830 | Implemented |
MA0841 # 02 Y:2022 | 02 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $24,631 | $155,407 | Implemented |
MA0841 # 03 Y:2022 | 03 | 2022 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $9,761 | $49,341 | Implemented |
MA0841 # 06 Y:2022 | 06 | 2022 | INSTALL OCCUPANCY SENSORS | $253 | $234 | Implemented |
MA0841 # 04 Y:2022 | 04 | 2022 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $5,842 | $500 | Implemented |
MA0809 # 01 Y:2019 | 01 | 2019 | USE SOLAR HEAT TO MAKE ELECTRICTY | $7,376 | $23,715 | Not Implemented |
MA0809 # 02 Y:2019 | 02 | 2019 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,745 | $11,800 | Not Implemented |
MA0809 # 06 Y:2019 | 06 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,036 | $3,057 | Implemented |
MA0809 # 04 Y:2019 | 04 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,772 | $1,000 | Implemented |
MA0809 # 03 Y:2019 | 03 | 2019 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,332 | $150 | Implemented |
MA0809 # 05 Y:2019 | 05 | 2019 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,114 | $4,500 | Implemented |
MA0788 # 01 Y:2018 | 01 | 2018 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $98,644 | $110,000 | Implemented |
MA0788 # 07 Y:2018 | 07 | 2018 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $4,043 | $18,200 | Not Implemented |
MA0788 # 06 Y:2018 | 06 | 2018 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,493 | $1,750 | Implemented |
MA0788 # 05 Y:2018 | 05 | 2018 | INSULATE BARE EQUIPMENT | $4,116 | $10,462 | Implemented |
MA0788 # 04 Y:2018 | 04 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,164 | $6,660 | Not Implemented |
MA0788 # 03 Y:2018 | 03 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $31,698 | $116,889 | Not Implemented |
MA0788 # 02 Y:2018 | 02 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43,627 | $17,006 | Implemented |
MA0761 # 02 Y:2016 | 02 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,889 | $2,685 | Not Implemented |
MA0761 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,969 | $6,409 | Not Implemented |
MA0761 # 04 Y:2016 | 04 | 2016 | MINIMIZE WATER USAGE | $3,035 | $4,050 | Not Implemented |
MA0761 # 05 Y:2016 | 05 | 2016 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $864 | $342 | Not Implemented |
MA0761 # 06 Y:2016 | 06 | 2016 | OPTIMIZE PLANT POWER FACTOR | $816 | $2,000 | Not Implemented |
MA0761 # 01 Y:2016 | 01 | 2016 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $22,997 | $134,000 | Not Implemented |