Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,809
matching recommendationsNAICS | 311 | Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0247 # 05 Y:2025 | 05 | 2025 | TURN OFF EQUIPMENT WHEN NOT IN USE | $399 | $0 | n/a |
DL0247 # 06 Y:2025 | 06 | 2025 | TURN OFF EQUIPMENT WHEN NOT IN USE | $993 | $0 | n/a |
DL0247 # 07 Y:2025 | 07 | 2025 | METER WASTE WATER | $34,580 | $145 | n/a |
DL0247 # 08 Y:2025 | 08 | 2025 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $27,958 | $200,000 | n/a |
DL0247 # 09 Y:2025 | 09 | 2025 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $116,551 | $1,000,000 | n/a |
UW2415 # 01 Y:2024 | 01 | 2024 | INSTALL OCCUPANCY SENSORS | $1,616 | $2,203 | n/a |
UW2415 # 02 Y:2024 | 02 | 2024 | ISOLATE HOT OR COLD EQUIPMENT | $7,755 | $3,047 | n/a |
UW2415 # 03 Y:2024 | 03 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $60,318 | $7,015 | n/a |
UW2415 # 04 Y:2024 | 04 | 2024 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $1,150,001 | $380,750 | n/a |
UW2415 # 05 Y:2024 | 05 | 2024 | INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT | $1,080,000 | $870,000 | n/a |
UW2415 # 06 Y:2024 | 06 | 2024 | MODIFY FACILITY TO AVOID EXCESS MAINTENANCE COSTS | $100,020 | $225,274 | n/a |
UW2415 # 07 Y:2024 | 07 | 2024 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,888 | $25,000 | n/a |
UW2415 # 08 Y:2024 | 08 | 2024 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,441 | $20,000 | n/a |
UW2415 # 09 Y:2024 | 09 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $29,064 | $195,867 | n/a |
UW2415 # 10 Y:2024 | 10 | 2024 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $32,733 | $55,000 | n/a |
UW2415 # 11 Y:2024 | 11 | 2024 | INITIATE A PROGRAM TO ACQUIRE ISO CERTIFICATION | $64,033 | $47,500 | n/a |
UW2415 # 12 Y:2024 | 12 | 2024 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $62,298 | $19,622 | n/a |
OR0803 # 01 Y:2024 | 01 | 2024 | ADD AIR SHIELDS TO TRUCKS TO INCREASE FUEL MILEAGE | $79,249 | $259,200 | n/a |
OR0803 # 02 Y:2024 | 02 | 2024 | INSULATE BARE EQUIPMENT | $6,565 | $7,289 | n/a |
OR0803 # 03 Y:2024 | 03 | 2024 | USE OPTIMUM TEMPERATURE | $6,284 | $0 | n/a |
OR0803 # 04 Y:2024 | 04 | 2024 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,111 | $0 | n/a |
OR0803 # 05 Y:2024 | 05 | 2024 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,591 | $3,426 | n/a |
OR0803 # 06 Y:2024 | 06 | 2024 | INSULATE BARE EQUIPMENT | $1,811 | $4,166 | n/a |
OR0802 # 01 Y:2024 | 01 | 2024 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,248 | $147 | n/a |
OR0802 # 02 Y:2024 | 02 | 2024 | INSULATE BARE EQUIPMENT | $2,952 | $500 | n/a |