Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsNAICS | 3114 | Fruit and Vegetable Preserving and Specialty Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0400 # 06 Y:2007 | 06 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $27,583 | $21,927 | Not Implemented |
UF0400 # 05 Y:2007 | 05 | 2007 | KEEP EQUIPMENT CLEAN | $3,059 | $87 | Implemented |
UF0400 # 04 Y:2007 | 04 | 2007 | INSTALL OCCUPANCY SENSORS | $4,182 | $928 | Implemented |
UF0400 # 03 Y:2007 | 03 | 2007 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $1,930 | $624 | Implemented |
UF0400 # 02 Y:2007 | 02 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,731 | $0 | Not Implemented |
UF0400 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,632 | $9,727 | Implemented |
UF0400 # 07 Y:2007 | 07 | 2007 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $653 | $511 | Not Implemented |
UF0400 # 08 Y:2007 | 08 | 2007 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $111,825 | $230 | Not Implemented |
OK0746 # 02 Y:2007 | 02 | 2007 | USE SOLAR HEAT FOR HEAT | $26,050 | $140,000 | Not Implemented |
OK0746 # 12 Y:2007 | 12 | 2007 | USE SOLAR HEAT TO MAKE ELECTRICTY | $24,000 | $840,000 | Not Implemented |
OK0746 # 11 Y:2007 | 11 | 2007 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $30,387 | $15,000 | Not Implemented |
OK0746 # 10 Y:2007 | 10 | 2007 | OPERATE BOILERS ON HIGH FIRE SETTING | $40,383 | $400 | Not Implemented |
OK0746 # 09 Y:2007 | 09 | 2007 | OPERATE BOILERS ON HIGH FIRE SETTING | $49,382 | $46,200 | Not Implemented |
OK0746 # 08 Y:2007 | 08 | 2007 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $39,725 | $63,500 | Not Implemented |
OK0746 # 07 Y:2007 | 07 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,881 | $0 | Implemented |
OK0746 # 06 Y:2007 | 06 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,881 | $3,256 | Implemented |
OK0746 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,287 | $3,000 | Implemented |
OK0746 # 04 Y:2007 | 04 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,580 | $4,541 | Implemented |
OK0746 # 03 Y:2007 | 03 | 2007 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $52,302 | $14,800 | Not Implemented |
OK0746 # 01 Y:2007 | 01 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $32,026 | $30,757 | Implemented |
UM0318 # 01 Y:2007 | 01 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,540 | $14,000 | Implemented |
UM0318 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,573 | $7,025 | Not Implemented |
UM0318 # 03 Y:2007 | 03 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,279 | $0 | Implemented |
UM0318 # 04 Y:2007 | 04 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,947 | $4,500 | Implemented |
UM0318 # 05 Y:2007 | 05 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,647 | $120 | Implemented |