Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
18
matching recommendationsNAICS | 311421 | Fruit and Vegetable Canning |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0528 # 02 Y:2014 | 02 | 2014 | INSULATE BARE EQUIPMENT | $9,196 | $7,095 | Not Implemented |
IA0528 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,031 | $10,568 | Not Implemented |
IA0528 # 04 Y:2014 | 04 | 2014 | USE PHOTOCELL CONTROLS | $2,865 | $630 | Not Implemented |
IA0528 # 05 Y:2014 | 05 | 2014 | INSTALL OCCUPANCY SENSORS | $453 | $525 | Not Implemented |
IA0528 # 06 Y:2014 | 06 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,974 | $1,053 | Not Implemented |
IA0528 # 07 Y:2014 | 07 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $408 | $970 | Not Implemented |
IA0528 # 08 Y:2014 | 08 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $288 | $70 | Not Implemented |
IA0528 # 01 Y:2014 | 01 | 2014 | HEAT WATER WITH EXHAUST HEAT | $14,601 | $9,600 | Not Implemented |
IC0110 # 10 Y:2005 | 10 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $473 | $3,388 | Implemented |
IC0110 # 09 Y:2005 | 09 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $17,156 | $81,881 | Implemented |
IC0110 # 08 Y:2005 | 08 | 2005 | OPTIMIZE PLANT POWER FACTOR | $13,904 | $70,000 | Implemented |
IC0110 # 07 Y:2005 | 07 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $7,443 | $15,000 | Not Implemented |
IC0110 # 06 Y:2005 | 06 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,956 | $0 | Implemented |
IC0110 # 05 Y:2005 | 05 | 2005 | IMPROVE COMBUSTION CONTROL CAPABILITY | $13,789 | $3,500 | Implemented |
IC0110 # 04 Y:2005 | 04 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $6,051 | $400 | Implemented |
IC0110 # 03 Y:2005 | 03 | 2005 | REPAIR OR REPLACE STEAM TRAPS | $29,831 | $1,638 | Implemented |
IC0110 # 02 Y:2005 | 02 | 2005 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $79,621 | $634,572 | Not Implemented |
IC0110 # 01 Y:2005 | 01 | 2005 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $106,617 | $213,420 | Implemented |