Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

63

matching recommendations
Reset
NAICS 311511 Fluid Milk Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0443 # 10 Y:2011 10 2011 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $4,822 $670 Not Implemented
UF0398 # 06 Y:2007 06 2007 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,060 $1,600 Not Implemented
UF0398 # 10 Y:2007 10 2007 OPTIMIZE PLANT POWER FACTOR $209,563 $17,000 Not Implemented
UF0398 # 09 Y:2007 09 2007 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,769 $19,429 Not Implemented
UF0398 # 08 Y:2007 08 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $547 $0 Not Implemented
UF0398 # 07 Y:2007 07 2007 USE OPTIMUM THICKNESS INSULATION $32,078 $6,105 Not Implemented
UF0398 # 05 Y:2007 05 2007 REPAIR OR REPLACE STEAM TRAPS $4,676 $218 Not Implemented
UF0398 # 04 Y:2007 04 2007 INSTALL OCCUPANCY SENSORS $806 $118 Not Implemented
UF0398 # 03 Y:2007 03 2007 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $477 $150 Not Implemented
UF0398 # 02 Y:2007 02 2007 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $940 $0 Not Implemented
UF0398 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $48,081 $134,669 Not Implemented
MI0142 # 06 Y:2007 06 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $14,779 $30 Not Implemented
MI0142 # 05 Y:2007 05 2007 TURN OFF EQUIPMENT WHEN NOT IN USE $22,540 $850 Implemented
MI0142 # 04 Y:2007 04 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $36,407 $68,250 Not Implemented
MI0142 # 03 Y:2007 03 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $46,802 $1,074 Not Implemented
MI0142 # 02 Y:2007 02 2007 TURN OFF EQUIPMENT WHEN NOT IN USE $70,674 $34 Implemented
MI0142 # 01 Y:2007 01 2007 HEAT WATER WITH EXHAUST HEAT $406,657 $46,000 Not Implemented
MI0125 # 01 Y:2006 01 2006 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $61,073 $1,290 Implemented
MI0125 # 02 Y:2006 02 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $28,374 $75,894 Not Implemented
MI0125 # 03 Y:2006 03 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $32,634 $35,000 Implemented
MI0125 # 04 Y:2006 04 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $24,438 $1,074 Implemented
MI0125 # 05 Y:2006 05 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $9,589 $850 Implemented
MI0125 # 06 Y:2006 06 2006 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $6,852 $4,800 Not Implemented
MI0125 # 07 Y:2006 07 2006 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,013 $395 Implemented
MI0099 # 06 Y:2005 06 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,355 $1,750 Implemented