Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

206

matching recommendations
Reset
NAICS 311520 Ice Cream and Frozen Dessert Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0780 # 03 Y:2004 03 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,654 $10,261 Implemented
GT0780 # 04 Y:2004 04 2004 UTILIZE A LESS EXPENSIVE COOLING METHOD $25,046 $92,125 Not Implemented
GT0780 # 05 Y:2004 05 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,772 $500 Implemented
GT0780 # 06 Y:2004 06 2004 COMBINE UTILITY METERS $23,320 $0 Not Implemented
GT0780 # 07 Y:2004 07 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,729 $1,209 Implemented
GT0780 # 08 Y:2004 08 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,512 $0 Not Implemented
GT0780 # 09 Y:2004 09 2004 REPAIR AND ELIMINATE STEAM LEAKS $7,453 $900 Implemented
GT0780 # 10 Y:2004 10 2004 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $12,344 $20,000 Not Implemented
GT0780 # 11 Y:2004 11 2004 RECOVER WASTE HEAT FROM EQUIPMENT $1,325 $1,600 Not Implemented
GT0780 # 12 Y:2004 12 2004 CONTROL PRESSURE ON STEAMER OPERATIONS $2,490 $800 Implemented
SF0275 # 01 Y:2004 01 2004 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $2,063 $739 Not Implemented
SF0275 # 02 Y:2004 02 2004 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $49,562 $39,000 Implemented
SF0275 # 03 Y:2004 03 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,238 $0 Implemented
SF0275 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,909 $3,688 Implemented
SF0275 # 05 Y:2004 05 2004 COVER OPEN TANKS $715 $1,469 Not Implemented
SF0275 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,604 $12,835 Not Implemented
SF0275 # 07 Y:2004 07 2004 INSTALL OCCUPANCY SENSORS $1,197 $4,096 Not Implemented
SF0275 # 08 Y:2004 08 2004 USE PHOTOCELL CONTROLS $613 $2,971 Not Implemented
SF0275 # 09 Y:2004 09 2004 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $30,592 $34,814 Not Implemented
UU0041 # 01 Y:2003 01 2003 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,352 $2,000 n/a
UU0041 # 02 Y:2003 02 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,207 $3,500 n/a
UU0041 # 03 Y:2003 03 2003 INSULATE BARE EQUIPMENT $1,080 $950 n/a
UU0041 # 04 Y:2003 04 2003 OPTIMIZE PLANT POWER FACTOR $31,340 $45,900 n/a
UU0041 # 05 Y:2003 05 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $14,860 $0 n/a
UU0041 # 06 Y:2003 06 2003 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $748 $0 n/a