Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2004 |
Principal Product | Dairy Product |
NAICS | 311520 - Ice Cream and Frozen Dessert Manufacturing |
SIC | 2026 - Fluid Milk |
Sales | $100,000,000-$500,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 18,200,000 Thousand Gallons |
Production Hrs. Annual | 4,200 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $724,659 | 9,844,053 | kWh | $0.07 |
Electricity Demand | $143,766 | 30,237 | kW-months/year | $4.75 |
Natural Gas | $1,022,553 | 85,928 | MMBtu | $11.90 |
TOTAL ENERGY COSTS | $1,957,590 | |||
RECOMMENDED SAVINGS* | $96,493 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $57,709 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $2,063 Cost: $739 |
$1,548 | 21,034 | $515 | 108 | - | - | - | - |
$1,548 21,034 kWh |
$515 108 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2441 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT |
Savings: $49,562 Cost: $39,000 |
- | - | - | - | $49,562 | 7,684 | - | - |
- - kWh |
- - kW-months/year |
$49,562 7,684 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $6,238 Cost: - |
$5,602 | 76,105 | $636 | 134 | - | - | - | - |
$5,602 76,105 kWh |
$636 134 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,909 Cost: $3,688 |
$1,605 | 21,810 | $304 | 64 | - | - | - | - |
$1,605 21,810 kWh |
$304 64 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2514 COVER OPEN TANKS |
Savings: $715 Cost: $1,469 |
- | - | - | - | $715 | 111 | - | - |
- - kWh |
- - kW-months/year |
$715 111 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,604 Cost: $12,835 |
$2,954 | 40,137 | $650 | 137 | - | - | - | - |
$2,954 40,137 kWh |
$650 137 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,197 Cost: $4,096 |
$935 | 12,705 | $262 | 55 | - | - | - | - |
$935 12,705 kWh |
$262 55 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $613 Cost: $2,971 |
$524 | 7,118 | $89 | 19 | - | - | - | - |
$524 7,118 kWh |
$89 19 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION |
Savings: $30,592 Cost: $34,814 |
- | - | - | - | - | - | $30,592 | 23,007,360 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$30,592 23,007,360 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $96,493 Cost: $99,612 |
$13,168 | 178,909 | $2,456 | 516 | $50,277 | 7,795 | $30,592 | 23,007,360 | $13,168 178,909 kWh |
$2,456 516 kW-months/year |
$50,277 7,795 MMBtu |
$30,592 23,007,360 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $57,709 Cost: $42,688 |
$7,207 | 97,915 | $940 | 198 | $49,562 | 7,684 | - | - | $7,207 97,915 kWh |
$940 198 kW-months/year |
$49,562 7,684 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal |