Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,427
matching recommendationsNAICS | 31161 | Animal Slaughtering and Processing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0169 # 06 Y:2008 | 06 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,528 | $1,240 | Not Implemented |
UD0785 # 01 Y:2008 | 01 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $199,480 | $23,400 | Not Implemented |
UD0785 # 02 Y:2008 | 02 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $66,859 | $121,500 | Implemented |
UD0785 # 03 Y:2008 | 03 | 2008 | REPLACE BOILER | $54,105 | $88,560 | Not Implemented |
UD0785 # 04 Y:2008 | 04 | 2008 | COVER OPEN TANKS | $13,767 | $55,000 | Not Implemented |
UD0785 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,828 | $98,908 | Implemented |
UD0785 # 06 Y:2008 | 06 | 2008 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $5,484 | $640 | Not Implemented |
UD0785 # 07 Y:2008 | 07 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,742 | $5,924 | Implemented |
UD0785 # 08 Y:2008 | 08 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,606 | $0 | Not Implemented |
UD0785 # 09 Y:2008 | 09 | 2008 | OPTIMIZE PLANT POWER FACTOR | $3,317 | $4,500 | Not Implemented |
UD0785 # 10 Y:2008 | 10 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,512 | $1,000 | Implemented |
UD0785 # 11 Y:2008 | 11 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,180 | $0 | Not Implemented |
GT0851 # 01 Y:2008 | 01 | 2008 | INCREASE AMOUNT OF CONDENSATE RETURNED | $48,953 | $8,350 | Not Implemented |
GT0851 # 02 Y:2008 | 02 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,800 | $0 | Not Implemented |
GT0851 # 03 Y:2008 | 03 | 2008 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $15,410 | $0 | Not Implemented |
GT0851 # 04 Y:2008 | 04 | 2008 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $18,784 | $450 | Not Implemented |
GT0851 # 05 Y:2008 | 05 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $13,289 | $2,260 | Not Implemented |
GT0851 # 06 Y:2008 | 06 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,838 | $1,832 | Not Implemented |
GT0851 # 07 Y:2008 | 07 | 2008 | MINIMIZE WATER USAGE | $20,751 | $3,000 | Not Implemented |
GT0851 # 08 Y:2008 | 08 | 2008 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $10,080 | $32,550 | Not Implemented |
GT0851 # 09 Y:2008 | 09 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,485 | $24,000 | Not Implemented |
GT0851 # 10 Y:2008 | 10 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,770 | $5,110 | Not Implemented |
IA0424 # 01 Y:2008 | 01 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $333 | $13 | Implemented |
IA0424 # 02 Y:2008 | 02 | 2008 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,811 | $134 | Not Implemented |
IA0424 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,627 | $3,004 | Implemented |