Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
478
matching recommendationsNAICS | 311612 | Meat Processed from Carcasses |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0262 # 03 Y:2008 | 03 | 2008 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,352 | $0 | Not Implemented |
SU0262 # 04 Y:2008 | 04 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,275 | $392 | Not Implemented |
SU0262 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,882 | $5,215 | Implemented |
SU0262 # 06 Y:2008 | 06 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $338 | $577 | Not Implemented |
SU0262 # 07 Y:2008 | 07 | 2008 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $183 | $308 | Not Implemented |
SU0262 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,400 | $10,328 | Implemented |
SU0262 # 09 Y:2008 | 09 | 2008 | INSTALL OCCUPANCY SENSORS | $320 | $716 | Not Implemented |
LL0284 # 01 Y:2007 | 01 | 2007 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $52,170 | $49,000 | Not Implemented |
LL0284 # 02 Y:2007 | 02 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $33,682 | $1,600 | Not Implemented |
LL0284 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,045 | $12,575 | Not Implemented |
LL0284 # 04 Y:2007 | 04 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $16,900 | $1,500 | Not Implemented |
LL0284 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,314 | $2,100 | Not Implemented |
LL0284 # 06 Y:2007 | 06 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,700 | $2,074 | Not Implemented |
LL0284 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,030 | $451 | Not Implemented |
LL0284 # 08 Y:2007 | 08 | 2007 | INSULATE BARE EQUIPMENT | $155 | $102 | Not Implemented |
UD0763 # 01 Y:2007 | 01 | 2007 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $36,135 | $5,242 | Implemented |
UD0763 # 02 Y:2007 | 02 | 2007 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $30,994 | $8,900 | Implemented |
UD0763 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,945 | $57,910 | Not Implemented |
UD0763 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,551 | $8,100 | Not Implemented |
UD0763 # 05 Y:2007 | 05 | 2007 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $2,275 | $0 | Not Implemented |
UD0763 # 06 Y:2007 | 06 | 2007 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $1,835 | $3,670 | Not Implemented |
IC0127 # 01 Y:2007 | 01 | 2007 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $14,659 | $0 | Implemented |
IC0127 # 02 Y:2007 | 02 | 2007 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $800 | $440 | Implemented |
IC0127 # 03 Y:2007 | 03 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,063 | $51,889 | Implemented |
IC0127 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $120 | $1,026 | Implemented |