IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

40

matching recommendations
Reset
NAICS 3118 Bakeries and Tortilla Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0359 # 01 Y:2011 01 2011 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $24,918 $64,500 Not Implemented
LL0359 # 02 Y:2011 02 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,575 $400 Implemented
LL0359 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $602 $385 Implemented
LL0359 # 05 Y:2011 05 2011 INSULATE BARE EQUIPMENT $515 $394 Not Implemented
LL0359 # 06 Y:2011 06 2011 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $514 $623 Not Implemented
LL0359 # 07 Y:2011 07 2011 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $421 $220 Not Implemented
LL0359 # 08 Y:2011 08 2011 INSTALL OCCUPANCY SENSORS $59 $240 Implemented
LL0162 # 01 Y:2003 01 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $15,597 $4,620 Implemented
LL0162 # 08 Y:2003 08 2003 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $14,078 $3,120 Implemented
LL0162 # 07 Y:2003 07 2003 INSTALL OCCUPANCY SENSORS $229 $205 Not Implemented
LL0162 # 06 Y:2003 06 2003 USE PHOTOCELL CONTROLS $938 $82 Not Implemented
LL0162 # 05 Y:2003 05 2003 OPTIMIZE PLANT POWER FACTOR $2,099 $2,310 Not Implemented
LL0162 # 04 Y:2003 04 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $7,770 $0 Implemented
LL0162 # 03 Y:2003 03 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $7,812 $683 Not Implemented
LL0162 # 02 Y:2003 02 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $11,299 $855 Not Implemented