IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,542

matching recommendations
Reset
NAICS 3118 Bakeries and Tortilla Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0330 # 08 Y:2008 08 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $631 $4,158 Not Implemented
MS0330 # 09 Y:2008 09 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $442 $2,040 Not Implemented
UW0017 # 01 Y:2008 01 2008 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,732 $17,259 Not Implemented
UW0017 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $694 $982 Implemented
UW0017 # 03 Y:2008 03 2008 UPGRADE OBSOLETE EQUIPMENT $338 $2,199 Not Implemented
UA0018 # 01 Y:2008 01 2008 UPGRADE CONTROLS ON COMPRESSORS $28,103 $15,000 Not Implemented
UA0018 # 02 Y:2008 02 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $22,622 $0 Implemented
UA0018 # 03 Y:2008 03 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $13,686 $5,000 Implemented
UA0018 # 04 Y:2008 04 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $21,032 $15,500 Not Implemented
UA0018 # 05 Y:2008 05 2008 RECOVER WASTE HEAT FROM EQUIPMENT $13,848 $6,050 Implemented
UA0018 # 06 Y:2008 06 2008 INSULATE BARE EQUIPMENT $5,592 $840 Implemented
UA0018 # 07 Y:2008 07 2008 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $14,000 $1,000 Implemented
UA0018 # 08 Y:2008 08 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $33,582 $71,934 Not Implemented
UA0018 # 09 Y:2008 09 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,739 $10,237 Not Implemented
UA0018 # 10 Y:2008 10 2008 INSTALL AUTOMATIC STACK DAMPER $78,268 $3,900 Not Implemented
UA0018 # 11 Y:2008 11 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $22,404 $30,900 Not Implemented
SF0355 # 01 Y:2008 01 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $904 $1,040 Implemented
SF0355 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,950 $26,488 Implemented
SF0355 # 03 Y:2008 03 2008 RECOVER WASTE HEAT FROM EQUIPMENT $25,511 $50,000 Not Implemented
SF0355 # 04 Y:2008 04 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $282 $1,174 Implemented
SF0355 # 05 Y:2008 05 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $422 $4,836 Not Implemented
SF0355 # 06 Y:2008 06 2008 SELL OIL TO RECYCLER $13,000 $0 Not Implemented
SF0355 # 07 Y:2008 07 2008 REUSE / RECYCLE/ SELL PAPER PRODUCTS $210 $0 Not Implemented
TT0021 # 01 Y:2008 01 2008 OPTIMIZE PLANT POWER FACTOR $3,500 $12,500 Implemented
TT0021 # 02 Y:2008 02 2008 INSULATE BARE EQUIPMENT $520 $1,700 Implemented