Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
70
matching recommendationsNAICS | 311812 | Commercial Bakeries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0232 # 01 Y:2020 | 01 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,992 | $2,233 | Not Implemented |
IC0232 # 03 Y:2020 | 03 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,953 | $2,750 | Not Implemented |
IC0232 # 04 Y:2020 | 04 | 2020 | REPAIR OR REPLACE STEAM TRAPS | $27,487 | $3,700 | Not Implemented |
IC0232 # 02 Y:2020 | 02 | 2020 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $10,592 | $3,287 | Not Implemented |
WM0023 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $283 | $494 | Implemented |
WM0023 # 01 Y:2013 | 01 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $4,080 | $5,760 | Not Implemented |
WM0023 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,281 | $1,625 | Implemented |
WM0023 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,135 | $39,312 | Not Implemented |
WM0023 # 07 Y:2013 | 07 | 2013 | IMPROVE SPACE COMFORT CONDITIONING | $50,218 | $27,650 | Not Implemented |
WM0023 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $1,427 | $630 | Implemented |
WM0023 # 03 Y:2013 | 03 | 2013 | USE SYNTHETIC LUBRICANT | $945 | $1,200 | Not Implemented |
WM0023 # 08 Y:2013 | 08 | 2013 | IMPROVE SPACE COMFORT CONDITIONING | $27,144 | $5,800 | Implemented |
BD0396 # 07 Y:2011 | 07 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,851 | $600 | Not Implemented |
BD0396 # 05 Y:2011 | 05 | 2011 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $6,576 | $300 | Not Implemented |
BD0396 # 03 Y:2011 | 03 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,092 | $30,000 | Not Implemented |
BD0396 # 04 Y:2011 | 04 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,736 | $20,080 | Not Implemented |
BD0396 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $3,890 | $4,200 | Not Implemented |
BD0396 # 01 Y:2011 | 01 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $72,574 | $19,000 | Not Implemented |
BD0396 # 02 Y:2011 | 02 | 2011 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $26,133 | $39,000 | Not Implemented |
IC0121 # 01 Y:2006 | 01 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $17,152 | $4,984 | Implemented |
IC0121 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,664 | $700 | Implemented |
IC0121 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $440 | $1,664 | Implemented |
IC0121 # 04 Y:2006 | 04 | 2006 | INSTALL TURBULATORS | $7,715 | $23,253 | Not Implemented |
IC0121 # 03 Y:2006 | 03 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,928 | $9,302 | Not Implemented |
IC0121 # 07 Y:2006 | 07 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $18,627 | $88,113 | Not Implemented |