Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,036
matching recommendationsNAICS | 311812 | Commercial Bakeries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0021 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $947 | $3,646 | Implemented |
TT0021 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $506 | $1,243 | Implemented |
TT0021 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,508 | $1,641 | Implemented |
TT0021 # 09 Y:2008 | 09 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $702 | $263 | Implemented |
TT0021 # 10 Y:2008 | 10 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,633 | $5,950 | Not Implemented |
MI0153 # 01 Y:2007 | 01 | 2007 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $342,569 | $290,000 | Not Implemented |
MI0153 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,866 | $54,000 | Not Implemented |
MI0153 # 03 Y:2007 | 03 | 2007 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,256 | $260 | Not Implemented |
MI0153 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,348 | $1,074 | Not Implemented |
MI0153 # 05 Y:2007 | 05 | 2007 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $628 | $2,610 | Not Implemented |
SF0343 # 01 Y:2007 | 01 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,112 | $220 | Implemented |
SF0343 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,925 | $6,063 | Implemented |
SF0343 # 03 Y:2007 | 03 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $385 | $364 | Implemented |
SF0343 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,009 | $9,569 | Implemented |
AM0529 # 01 Y:2007 | 01 | 2007 | INSTALL HYDROGEN FUEL CELL | $59,020 | $250,000 | Not Implemented |
AM0529 # 02 Y:2007 | 02 | 2007 | OPTIMIZE PLANT POWER FACTOR | $41,500 | $86,400 | Implemented |
AM0529 # 03 Y:2007 | 03 | 2007 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $18,360 | $8,240 | Not Implemented |
AM0529 # 04 Y:2007 | 04 | 2007 | USE SOLAR HEAT TO MAKE ELECTRICTY | $3,210 | $52,600 | Not Implemented |
AM0529 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $3,110 | $2,165 | Implemented |
AM0529 # 06 Y:2007 | 06 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,160 | $360 | Implemented |
AM0529 # 07 Y:2007 | 07 | 2007 | USE SYNTHETIC LUBRICANT | $2,027 | $0 | Not Implemented |
AM0529 # 08 Y:2007 | 08 | 2007 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $968 | $0 | Implemented |
MI0143 # 01 Y:2007 | 01 | 2007 | HEAT WATER WITH EXHAUST HEAT | $144,259 | $23,000 | Not Implemented |
MI0143 # 02 Y:2007 | 02 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $47,797 | $1,074 | Not Implemented |
MI0143 # 03 Y:2007 | 03 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $14,665 | $30 | Not Implemented |