Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
38
matching recommendationsNAICS | 311812 | Commercial Bakeries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0402 # 08 Y:2005 | 08 | 2005 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $687 | $3,000 | Not Implemented |
AS0402 # 01 Y:2005 | 01 | 2005 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $15,919 | $11,000 | Implemented |
AS0402 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $13,755 | $1,000 | Implemented |
AS0402 # 03 Y:2005 | 03 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $12,630 | $1,000 | Implemented |
AS0402 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,620 | $50,533 | Implemented |
AS0402 # 05 Y:2005 | 05 | 2005 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $4,823 | $1,000 | Not Implemented |
AS0402 # 06 Y:2005 | 06 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $4,059 | $18,400 | Implemented |
AS0402 # 07 Y:2005 | 07 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,059 | $2,000 | Not Implemented |
CO0566 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $1,000 | $640 | Not Implemented |
CO0566 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,170 | $6,180 | Not Implemented |
CO0566 # 05 Y:2005 | 05 | 2005 | USE SOLAR HEAT TO HEAT MAKE-UP AIR | $5,080 | $38,680 | Not Implemented |
CO0566 # 04 Y:2005 | 04 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,010 | $20,000 | Implemented |
CO0566 # 03 Y:2005 | 03 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,560 | $300 | Implemented |
CO0566 # 02 Y:2005 | 02 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $300 | $550 | Not Implemented |
CO0566 # 01 Y:2005 | 01 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,690 | $2,060 | Not Implemented |
AS0401 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,061 | $7,690 | Not Implemented |
AS0401 # 08 Y:2005 | 08 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $255 | $553 | Not Implemented |
AS0401 # 07 Y:2005 | 07 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $463 | $100 | Not Implemented |
AS0401 # 06 Y:2005 | 06 | 2005 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $721 | $1,300 | Not Implemented |
AS0401 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $859 | $806 | Not Implemented |
AS0401 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,540 | $5,000 | Not Implemented |
AS0401 # 03 Y:2005 | 03 | 2005 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $6,374 | $5,000 | Not Implemented |
AS0401 # 01 Y:2005 | 01 | 2005 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $129,307 | $21,049 | Not Implemented |
AS0401 # 09 Y:2005 | 09 | 2005 | INSTALL OCCUPANCY SENSORS | $88 | $525 | Not Implemented |
IC0096 # 14 Y:2005 | 14 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $744 | $781 | Not Implemented |