Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
117
matching recommendationsNAICS | 3119 | Other Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0860 # 04 Y:2009 | 04 | 2009 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $4,140 | $6,750 | Not Implemented |
GT0860 # 05 Y:2009 | 05 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,419 | $7,066 | Implemented |
GT0860 # 06 Y:2009 | 06 | 2009 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,213 | $12,000 | Not Implemented |
GT0860 # 07 Y:2009 | 07 | 2009 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $2,199 | $4,250 | Not Implemented |
GT0860 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,084 | $16,350 | Implemented |
GT0860 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,361 | $14,795 | Implemented |
GT0855 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,022 | $9,780 | Implemented |
GT0855 # 02 Y:2008 | 02 | 2008 | INSTALL OCCUPANCY SENSORS | $1,127 | $1,120 | Implemented |
GT0855 # 03 Y:2008 | 03 | 2008 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $10,291 | $19,600 | Not Implemented |
GT0855 # 04 Y:2008 | 04 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $19,920 | $17,000 | Not Implemented |
GT0855 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $795 | $500 | Implemented |
GT0855 # 06 Y:2008 | 06 | 2008 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $834 | $2,100 | Not Implemented |
GT0855 # 07 Y:2008 | 07 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,537 | $2,500 | Not Implemented |
GT0855 # 08 Y:2008 | 08 | 2008 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,089 | $1,350 | Not Implemented |
GT0841 # 01 Y:2007 | 01 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,121 | $1,250 | Implemented |
GT0841 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $160 | $132 | Not Implemented |
GT0841 # 03 Y:2007 | 03 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,424 | $1,967 | Implemented |
GT0841 # 04 Y:2007 | 04 | 2007 | USE SYNTHETIC LUBRICANT | $4,306 | $0 | Implemented |
GT0841 # 05 Y:2007 | 05 | 2007 | UPGRADE OBSOLETE EQUIPMENT | $5,731 | $0 | Not Implemented |
GT0841 # 06 Y:2007 | 06 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,623 | $1,000 | Not Implemented |
GT0841 # 07 Y:2007 | 07 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,453 | $9,501 | Implemented |
GT0841 # 08 Y:2007 | 08 | 2007 | SCHEDULE USE OF ELEVATORS TO CONSERVE ENERGY | $2,640 | $15,000 | Not Implemented |
GT0841 # 09 Y:2007 | 09 | 2007 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $1,780 | $15,000 | Not Implemented |
GT0811 # 01 Y:2005 | 01 | 2005 | IMPROVE LUBRICATION PRACTICES | $3,405 | $0 | Implemented |
GT0811 # 02 Y:2005 | 02 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,824 | $20,700 | Implemented |