Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
11
matching recommendationsNAICS | 311930 | Flavoring Syrup and Concentrate Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0874 # 01 Y:2013 | 01 | 2013 | OPTIMIZE PLANT POWER FACTOR | $23,112 | $20,000 | Not Implemented |
UD0874 # 02 Y:2013 | 02 | 2013 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $16,400 | $200 | Implemented |
UD0874 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,108 | $38,600 | Not Implemented |
UD0874 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,148 | $51,240 | Not Implemented |
UD0874 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,338 | $6,405 | Not Implemented |
UD0874 # 06 Y:2013 | 06 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $95,537 | $39,093 | Not Implemented |
UD0874 # 07 Y:2013 | 07 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,535 | $0 | Implemented |
UD0874 # 08 Y:2013 | 08 | 2013 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $58,058 | $88,200 | Not Implemented |
UD0874 # 09 Y:2013 | 09 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,928 | $12,300 | Not Implemented |
UD0874 # 10 Y:2013 | 10 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $10,382 | $30,000 | Not Implemented |
UD0874 # 11 Y:2013 | 11 | 2013 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $317,641 | $906,381 | Not Implemented |