Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,033
matching recommendationsNAICS | 3121 | Beverage Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0472 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,003 | $19,142 | Implemented |
SF0472 # 05 Y:2015 | 05 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,245 | $18,586 | Not Implemented |
SF0469 # 01 Y:2015 | 01 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,953 | $0 | Not Implemented |
SF0469 # 02 Y:2015 | 02 | 2015 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $6,607 | $2,460 | Not Implemented |
SF0469 # 03 Y:2015 | 03 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $152 | $85 | Implemented |
SF0469 # 04 Y:2015 | 04 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,689 | $8,237 | Not Implemented |
SF0469 # 05 Y:2015 | 05 | 2015 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $660 | $1,671 | Not Implemented |
SF0469 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,789 | $82,161 | Implemented |
DL0147 # 01 Y:2015 | 01 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,550 | $9,700 | Not Implemented |
DL0147 # 02 Y:2015 | 02 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $16,890 | $32,055 | Not Implemented |
DL0147 # 03 Y:2015 | 03 | 2015 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $27,680 | $73,960 | Implemented |
DL0147 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,470 | $21,000 | Implemented |
MI0279 # 01 Y:2015 | 01 | 2015 | INCREASE EFFICIENCY OF TRUCKS | $30,426 | $29,000 | Not Implemented |
MI0279 # 02 Y:2015 | 02 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $29,100 | $80,000 | Not Implemented |
MI0279 # 03 Y:2015 | 03 | 2015 | RECOVER AND REUSE COOLING WATER | $12,134 | $497 | Implemented |
MI0279 # 04 Y:2015 | 04 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $11,413 | $12,060 | Implemented |
MI0279 # 05 Y:2015 | 05 | 2015 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,141 | $2,100 | Implemented |
MI0279 # 06 Y:2015 | 06 | 2015 | USE OPTIMUM THICKNESS INSULATION | $4,666 | $1,810 | Implemented |
MI0279 # 07 Y:2015 | 07 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,329 | $40 | Implemented |
MI0279 # 08 Y:2015 | 08 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,877 | $2,520 | Implemented |
MI0279 # 09 Y:2015 | 09 | 2015 | INSULATE BARE EQUIPMENT | $1,612 | $482 | Implemented |
MI0279 # 10 Y:2015 | 10 | 2015 | INSTALL OCCUPANCY SENSORS | $1,456 | $1,782 | Not Implemented |
MI0279 # 11 Y:2015 | 11 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,317 | $3,280 | Not Implemented |
MI0279 # 12 Y:2015 | 12 | 2015 | USE PHOTOCELL CONTROLS | $1,139 | $480 | Implemented |
MI0279 # 13 Y:2015 | 13 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $634 | $1,760 | Implemented |