Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

797

matching recommendations
Reset
NAICS 312111 Soft Drink Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
DL0008 # 04 Y:2007 04 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $20,801 $175,000 Implemented
DL0008 # 05 Y:2007 05 2007 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $18,000 $1,000 Implemented
DL0008 # 06 Y:2007 06 2007 REPLACE BOILER $12,509 $27,400 Not Implemented
DL0008 # 07 Y:2007 07 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,978 $2,105 Implemented
DL0008 # 08 Y:2007 08 2007 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $3,800 $900 Implemented
DL0008 # 09 Y:2007 09 2007 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $2,893 $14,000 Not Implemented
DL0008 # 10 Y:2007 10 2007 INSTALL OCCUPANCY SENSORS $754 $285 Implemented
IA0414 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,590 $3,793 Not Implemented
IA0414 # 02 Y:2007 02 2007 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $501 $118 Not Implemented
IA0414 # 03 Y:2007 03 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $807 $262 Not Implemented
IA0414 # 04 Y:2007 04 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,004 $163 Not Implemented
IA0414 # 05 Y:2007 05 2007 INSTALL / REPAIR INSULATION ON STEAM LINES $2,721 $1,300 Not Implemented
UM0321 # 01 Y:2007 01 2007 USE HEAT PUMP FOR SPACE CONDITIONING $33,455 $21,730 Not Implemented
UM0321 # 02 Y:2007 02 2007 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $11,520 $21,700 Not Implemented
UM0321 # 03 Y:2007 03 2007 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $9,993 $1,000 Implemented
UM0321 # 04 Y:2007 04 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,307 $1,000 Implemented
UM0321 # 05 Y:2007 05 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,338 $0 Implemented
UM0321 # 06 Y:2007 06 2007 TREAT AND REUSE RINSE WATERS $3,084 $8,021 Not Implemented
UM0321 # 07 Y:2007 07 2007 INSTALL OCCUPANCY SENSORS $1,558 $5,130 Implemented
UM0319 # 01 Y:2007 01 2007 RECOVER AND REUSE COOLING WATER $56,454 $0 Not Implemented
UM0319 # 02 Y:2007 02 2007 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $31,763 $0 Not Implemented
UM0319 # 03 Y:2007 03 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $28,235 $20,000 Implemented
UM0319 # 04 Y:2007 04 2007 REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING $33,973 $300,000 Implemented
UM0319 # 05 Y:2007 05 2007 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $20,590 $0 Not Implemented
UM0319 # 06 Y:2007 06 2007 MINIMIZE WATER USAGE $15,684 $0 Not Implemented