Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
797
matching recommendationsNAICS | 312111 | Soft Drink Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0008 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,801 | $175,000 | Implemented |
DL0008 # 05 Y:2007 | 05 | 2007 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $18,000 | $1,000 | Implemented |
DL0008 # 06 Y:2007 | 06 | 2007 | REPLACE BOILER | $12,509 | $27,400 | Not Implemented |
DL0008 # 07 Y:2007 | 07 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,978 | $2,105 | Implemented |
DL0008 # 08 Y:2007 | 08 | 2007 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $3,800 | $900 | Implemented |
DL0008 # 09 Y:2007 | 09 | 2007 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $2,893 | $14,000 | Not Implemented |
DL0008 # 10 Y:2007 | 10 | 2007 | INSTALL OCCUPANCY SENSORS | $754 | $285 | Implemented |
IA0414 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,590 | $3,793 | Not Implemented |
IA0414 # 02 Y:2007 | 02 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $501 | $118 | Not Implemented |
IA0414 # 03 Y:2007 | 03 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $807 | $262 | Not Implemented |
IA0414 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,004 | $163 | Not Implemented |
IA0414 # 05 Y:2007 | 05 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,721 | $1,300 | Not Implemented |
UM0321 # 01 Y:2007 | 01 | 2007 | USE HEAT PUMP FOR SPACE CONDITIONING | $33,455 | $21,730 | Not Implemented |
UM0321 # 02 Y:2007 | 02 | 2007 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $11,520 | $21,700 | Not Implemented |
UM0321 # 03 Y:2007 | 03 | 2007 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $9,993 | $1,000 | Implemented |
UM0321 # 04 Y:2007 | 04 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,307 | $1,000 | Implemented |
UM0321 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,338 | $0 | Implemented |
UM0321 # 06 Y:2007 | 06 | 2007 | TREAT AND REUSE RINSE WATERS | $3,084 | $8,021 | Not Implemented |
UM0321 # 07 Y:2007 | 07 | 2007 | INSTALL OCCUPANCY SENSORS | $1,558 | $5,130 | Implemented |
UM0319 # 01 Y:2007 | 01 | 2007 | RECOVER AND REUSE COOLING WATER | $56,454 | $0 | Not Implemented |
UM0319 # 02 Y:2007 | 02 | 2007 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $31,763 | $0 | Not Implemented |
UM0319 # 03 Y:2007 | 03 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $28,235 | $20,000 | Implemented |
UM0319 # 04 Y:2007 | 04 | 2007 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $33,973 | $300,000 | Implemented |
UM0319 # 05 Y:2007 | 05 | 2007 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $20,590 | $0 | Not Implemented |
UM0319 # 06 Y:2007 | 06 | 2007 | MINIMIZE WATER USAGE | $15,684 | $0 | Not Implemented |